-
- Nabeel A Herial, Asif A Khan, Gregory T Sherr, Mushtaq H Qureshi, M Fareed K Suri, and Adnan I Qureshi.
- *Zeenat Qureshi Stroke Institute and ‡Department of Neurosurgery, CentraCare Health, St. Cloud, Minnesota.
- Neurosurgery. 2015 Sep 1;11 Suppl 3:404-11; discussion 411.
BackgroundThe US Food and Drug Administration recently approved a detachable-tip microcatheter, the Apollo microcatheter (eV3, Inc, Irvine, California), to prevent catheter entrapment during embolization of brain arteriovenous malformations (AVMs) using liquid embolic systems.ObjectiveTo report technical aspects and clinical results of cerebral embolizations with the Apollo microcatheter in 7 embolizations in 3 adult patients.MethodsA 62-year-old man presented with an AVM in the parieto-occipital region measuring 3.6 × 1.6 cm with major cortical feeders from the right middle cerebral artery (MCA) and minor contribution from the distal right anterior cerebral artery. Two pedicles originating from the MCA were embolized. A 48-year-old woman presented with a left frontal AVM measuring 3.3 × 1.8 cm with arterial feeders from the left MCA, left middle meningeal artery, and contralateral anterior cerebral artery. Three pedicles originating from the left MCA were embolized. A 76-year-old man presented with an arteriovenous fistula with multiple fistulous connections and feeders from both vertebral and occipital arteries and the left posterior cerebral artery draining into the left transverse, torcula, and left sigmoid sinus. Two major occipital artery feeders were embolized.ResultsSeven Apollo microcatheters were used with the Onyx 18 liquid embolic system. The length of the detachable tip was 15 mm in 2 and 30 mm in 5 embolizations. The mean microcatheter in-position time within the pedicle was 20 minutes. Detachment of tip occurred in 3 instances. No limitations in accessing target arterial feeders and safe tip disengagement were noted despite prolonged injection times.ConclusionOur initial experience supports the feasibility, safety, and effectiveness of detachable-tip microcatheters in treating brain AVMs and arteriovenous fistulas.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.