• J Clin Monit Comput · Apr 2012

    Comparative Study

    Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

    • Guo Chen, Elena Chung, Lingzhong Meng, Brenton Alexander, Trung Vu, Joseph Rinehart, and Maxime Cannesson.
    • Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, People's Republic of China.
    • J Clin Monit Comput. 2012 Apr 1;26(2):133-40.

    AbstractThe Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperative hypo- or hypertension compared to standard BP monitoring by cuff (BP(CUFF)). We studied25 patients (ASA I-III) undergoing either abdominal or orthopedic surgery. BP(CUFF) was monitored every 5 min from the introduction of anesthesia, while BP(NXF) was monitored continuously on the opposite arm. When systolic BP(NXF) (SBP(NXF)) decreased or increased more than 20% relative to baseline SBP(NXF), a standard BP(CUFF) measurement was taken to compare values. In addition, the time interval between the 20% change in SBP(NXF) and the next scheduled standard SBP(CUFF) measurement was recorded for each event. The mean length of surgery was 3.0 ± 0.3 h. Patients presented with 11 ± 4 episodes of hypotension and 12 ± 4 episodes of hypertension during the surgery. If BP(CUFF) had been used, this would have resulted in 21 ± 7 min of hypotension and 20 ± 10 min of hypertension. If hemodynamic changes seen by SBP(NXF) were appropriately treated, an average of 7 ± 1 min/h of hypotension time, 7 ± 2 min/h of hypertension time and 14 ± 3 min per hour of hypo- or hypertension time may have been identified. The Nexfin BP has the potential to decrease the time of hypotension and hypertension compared to conventional intermittent BP(CUFF) monitoring. Therefore, this device has the potential to positively impact clinical outcomes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…