    Intraoperative MRI electrical noise and monitor ECG filters affect arrhythmia detection and identification.

    • Melissa Bailey, Gwynne Kirchen, Bridget Bonaventura, Kelly Rosborough, Mahmoud Abdel-Rasoul, and Roger Dzwonczyk.
    • Department of Anesthesiology, The Ohio State University, Columbus, OH 43210, USA. melissaraebailey@gmail.com
    • J Clin Monit Comput. 2012 Jun 1;26(3):157-61.

    AbstractMost electrical equipment in the modern operating room (OR) radiates electrical noise (EN) that can interfere with patient monitors. We have described the EN that an intraoperative magnetic resonance imaging (iMRI) system emits and have shown that this high-energy EN diminishes the quality of the ECG waveform during iMRI scans in our neurosurgical OR. We have also shown that the ECG signal filters in our iMRI-compatible patient monitor reduce this interference but, in the process, disturb the true morphology of the displayed waveform. This simulation study evaluates how iMRI-generated EN affects the ability of the anesthetist to detect and identify ECG arrhythmias and whether the patient monitor's ECG signal filters can improve arrhythmia recognition. Using an ECG simulator, we generated Lead II and V5 ECG signal segments that contained either no arrhythmia or one of four common cardiac arrhythmias. We filtered the ECG segments with four filters available on our iMRI-compatible monitor (Veris MR, MEDRAD Inc., Indianola, PA USA). We then digitized the segments and mixed simulated iMRI EN into the resultant tracings. With institutional approval and written informed consent, board-certified anesthesiologists reviewed the tracings, determined if an arrhythmia was present and identified the arrhythmia. We conducted the study anonymously. We reported the data as percent correct arrhythmia detection and correct arrhythmia identification. Thirty-one anesthesiologists completed the study. Overall, the participants correctly detected 79.5% (95% CI: 77.2, 81.7%) of the arrhythmias and correctly identified 62.5% (95% CI: 59.8, 65.3%) of the arrhythmias, regardless of EN presence. Although the proportions among monitor noise filters studied were not significant, the manufacturer-designated MR5 Veris MR filter optimized arrhythmia detection and arrhythmia identification for our participants, regardless if EN was present in the ECG tracings. In the neurosurgical OR, the anesthetist must be able to effectively monitor a patient in the presence of iMRI-generated EN. Depending on the OR design, the patient may be out of the anesthetist's direct view during a scan procedure. The anesthetist must rely on monitored physiologic parameters to assess patient status during this time. He/she should be familiar with his/her monitor's filtering capabilities and routinely adjust the ECG filters to achieve the best compromise between minimized EN effects and maximized displayed ECG signal quality.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.