• Spine · Jul 2015

    Polyelectrolyte Complex Carrier Enhances Therapeutic Efficiency and Safety Profile of BMP-2 in Porcine Lumbar Interbody Fusion Model.

    • Ming Wang, Sunny Akogwu Abbah, Tao Hu, Raymond Wing Moon Lam, Soo Yein Toh, Tong Liu, Simon M Cool, Kishore Bhakoo, and Jun Li.
    • *Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore †Singapore Institute of Manufacturing Technology, A*STAR, Singapore ‡Institute of Medical Biology, A*STAR, Singapore §Singapore Bioimaging Consortium, A*STAR, Singapore ¶Institute of Materials Research and Engineering, A*STAR, Singapore; and ‖Department of Biomedical Engineering, Faculty of Engineering, National University of Singapore, Singapore.
    • Spine. 2015 Jul 1; 40 (13): 964-73.

    Study DesignPorcine lumbar interbody fusion model.ObjectiveThis study evaluates the effect of polyelectrolyte complex (PEC) carrier in enhancing the therapeutic efficiency and safety profile of bone morphogenetic protein-2 (BMP-2) in a large animal model.Summary Of Background DataExtremely large amounts of BMP-2 are administered to achieve consistent spinal fusion, which has led to complications. Heparin-modified PEC carrying reduced BMP-2 doses of 0.5 μg was demonstrated to achieve consistent spinal fusion with reduction of complications in rodent model. The purpose of this study was to evaluate whether PEC could improve the therapeutic efficiency of BMP-2 in porcine model.MethodsThree-segment (L3-L6) anterior lumbar interbody fusions with instrumentation were performed on 6 pigs using 3 different doses of BMP-2, namely, (1) 50 μg, (2) 150 μg, and (3) 300 μg. The BMP-2 was delivered using heparin-modified alginate microbeads loaded into biodegradable cage. Fusion performance was evaluated after 3 months.ResultsManual palpation and micro-computed tomography showed consistent fusion in all experimental groups. Heterotopic bone formation beyond the cage implant area was more evident in group 2 and group 3 than in group 1. Similarly, superior bone microstructure was observed in the new bone with the lowered BMP-2 dose. Biomechanical evaluation revealed enhanced stiffness of the operated segments compared with nonoperated segments (P < 0.05). Mechanical stability was maintained despite dose reduction of BMP-2. Although the mineral apposition rate was higher in group 3, unsatisfactory bony microstructure with decreased trabecular number was observed in group 3 compared with group 1.ConclusionPEC carrying low doses of BMP-2 achieved consistent interbody fusion. We observed dose-related reduction in heterotopic ossification without compromising the stability of the fused segments. PEC carrier reduces the efficacious doses of BMP-2. This could enhance the safety profile of BMP-2 and reduce dose- and carrier-related complications.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.