• Spine · Oct 2015

    In Vivo Magnetic Resonance Imaging Evaluation of Porous Tantalum Interbody Fusion Devices in a Porcine Spinal Arthrodesis Model.

    • Zhiyu Zhou, Fuxin Wei, Sheng Huang, Manman Gao, Haisheng Li, Hans Stødkilde-Jørgensen, Martin Lind, Cody Bünger, and Xuenong Zou.
    • *Orthopaedic Research Lab and 3MR Research Center/Institute of Clinical Medicine, Aarhus University Hospital, 8000 Aarhus C, Denmark †Department of Spinal Surgery/Orthopaedic Research Institute, The First Affiliated Hospital of Sun Yat-sen University, 510080 Guangzhou, PR China ‡The Medical School of Shenzhen University, 518061 Shenzhen, PR China; and §Department of Orthopaedic Surgey, UT Southwestern Medical Center, Dallas, TX.
    • Spine. 2015 Oct 1; 40 (19): 1471-8.

    Study DesignAnimal experimental study.ObjectiveTo investigate the use of magnetic resonance (MR) imaging in the assessment of lumbar interbody fusion using porous tantalum implants in a porcine spinal fusion model.Summary Of Background DataPorous tantalum has been used successfully as a spinal interbody fusion device. However, to our knowledge, there has been no consensus on the optimal technique for evaluating spinal fusion when using porous tantalum implants.MethodsTwelve 12-week-old female Danish Landrace pigs underwent 3 levels of anterior lumbar interbody fusion at L2-3, L4-5 and L6-7. One level was fused using a solid porous tantalum cage with pedicle screw fixation. The other 2 levels were fused using a hollow porous tantalum ring packed with autograft and stabilized anteriorly with staples. Six months postoperatively, T1-weighted, T2-weighted, and gadolinium-DTPA contrast-enhanced MRI were obtained on a GE 1.5-T unit. After sacrifice, conventional radiograph and histological examination were carried out.ResultsEleven pigs went through the experiment without complications. On all the MR sequences, there were significant higher signal intensity bands at the vertebrae-implant interface of nonfused segments compared with that of fused segments and the vertebral bone and implants themselves (P < 0.001). There was an agreement between histological findings of fibrous tissues surrounding the implants and the high signal intensity band on T1- and T2-weighted MR images respectively (sensitivity 69.6% and 56.5%, specificity 90.7% and 95.3%), both of which were superior to conventional radiograph images (sensitivity 52.2%, specificity 97.7%), especially the T1-weighted MR images.ConclusionMR imaging could be an effective and noninvasive way to determine the fusion status of tantalum metal implants. Compared with T2-weighted MR imaging and conventional radiograph, T1-weighted spin-echo MR imaging is more sensitive and specific in detecting nonunion via the lucency between the vertebral body and tantalum metal device.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…