• Spine · Aug 2015

    Evaluation of the Fixation Strength of Pedicle Screws Using Cortical Bone Trajectory: What Is the Ideal Trajectory for Optimal Fixation?

    • Keitaro Matsukawa, Eiko Taguchi, Yoshiyuki Yato, Hideaki Imabayashi, Naobumi Hosogane, Takashi Asazuma, and Koichi Nemoto.
    • *Department of Orthopaedic Surgery, National Defense Medical College, Tokorozawa, Saitama, Japan; and †Department of Orthopaedic Surgery, National Hospital Organization, Murayama Medical Center, Musashimurayama, Tokyo, Japan.
    • Spine. 2015 Aug 1; 40 (15): E873-8.

    Study DesignIn vivo analysis of insertional torque of pedicle screws using cortical bone trajectory (CBT) technique.ObjectiveTo investigate factors contributing to the fixation strength of CBT screws and to clarify the ideal cortical trajectory for lumbar fusion.Summary Of Background DataCBT has developed as a new minimally invasive technique of lumbar instrumentation. Despite biomechanical studies demonstrating the superior characteristics of CBT, no study has elucidated the most suitable path for optimal fixation or compared the fixation within variations of trajectory.MethodsThe insertional torque of pedicle screws using CBT was measured intraoperatively in 72 consecutive patients. The detailed positions of a total of 268 screws were confirmed using postoperative reconstruction computed tomographic scans and were analyzed to identify factors contributing to the level of insertional torque. Investigated factors were as follows: (1) age, (2) bone mineral density of the femoral neck and lumbar vertebrae by dual-energy x-ray absorptiometry; (3) the pedicle width and height, (4) the length of the implant, (5) total screw length within the vertebra, (6) the screw length within the vertebral body, (7) the screw length within the lamina, (8) the cephalad and lateral angle of the trajectory, and (9) the distance from the long axis of the screw to the inferior and medial borders of the pedicle.ResultsMultiple regression analysis showed that bone mineral density of the femoral neck, screw length within the lamina, and cephalad angle were significant independent factors affecting torque.ConclusionThe fixation of CBT screws varied depending on technical factors (cephalad angle and screw length within the lamina) as well as the individual patient factor of bone mineral density. The ideal trajectory was directed 25° to 30° cranially along the inferior border of the pedicle so as to obtain maximum contact with the lamina and sufficient length within the vertebral body.Level Of Evidence2.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.