• Spine · Dec 2015

    Range of Motion in Segmental Versus Nonsegmental UHWMPE Sublaminar Wire Growth Guidance Type Constructs for Early Onset Scoliosis Correction.

    • Alex K Roth, Albert J van der Veen, Rob Bogie, Paul C Willems, Bert van Rietbergen, Lodewijk W van Rhijn, and Jacobus J Arts.
    • *Department of Orthopedic Surgery, Research School CAPHRI, Maastricht University Medical Center, Maastricht, The Netherlands †Department of Orthopedic Surgery, VU University Medical Center, Amsterdam, The Netherlands ‡Orthopedic Biomechanics, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
    • Spine. 2015 Dec 1; 40 (23): E1212-8.

    Study DesignAn in vitro biomechanical study in porcine thoracic spine segments comparing range of motion (ROM) in segmental versus multiple nonsegmental ultrahigh molecular weight polyethylene (UHMWPE) sublaminar wire constructs.ObjectiveTo determine the effect of varying instrumentation (wire) density in an UHMWPE sublaminar wire construct for patients with early-onset scoliosis (EOS) to find an optimal wire density, which allows maximum growth whereas still providing adequate correction and fixation.Summary Of Background DataUHMWPE sublaminar wires in a segmental construct did not negatively affect longitudinal spinal growth during a 24-week period in an ovine model; application in growth guidance system for EOS may therefore be feasible. To avoid ectopic bone formation as much as possible, a reduction of instrumented levels, without affecting spinal stabilization, is desirable.MethodsROM of 9 porcine thoracic spines (T6-T14) was determined in flexion/extension (FE), lateral bending (LB), and axial rotation up to ± 4 Nm. Tests were performed for the uninstrumented spine in a segmental construct with UHMWPE sublaminar wires and dual pedicle screws at the most caudal level, and in four nonsegmental constructs that were attained by stepwise removal of the most caudal wire.ResultsSegmental instrumentation led to a decrease in total ROM by approximately 70% for both FE and LB. A stepwise increase in ROM with decreasing number of consecutively instrumented levels was most clearly observed in LB. However, consistent significant but also relevant substantial differences in ROM for both FE and LB were noted only when comparing two and one consecutively instrumented end levels (P < 0.05).ConclusionA construct with two consecutive end levels instrumented with UHMWPE sublaminar wires seems to provide the best balance between spinal stabilization and minimizing the number of instrumented levels and thereby surgical exposure, which is crucial for allowing longitudinal growth.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…