• Spine · Dec 2015

    A non-destructive method to distinguish the internal constituent architecture of the intervertebral discs using 9.4 Tesla Magnetic Resonance Imaging.

    • Vithanage N Wijayathunga, John P Ridgway, Eileen Ingham, Darren Treanor, Duane Carey, Andy Bulpitt, Derek Magee, Robin Damion, and Ruth K Wilcox.
    • *Institute of Medical and Biological Engineering, University of Leeds, Leeds, United Kingdom†Division of Medical Physics, University of Leeds, Leeds, United Kingdom‡The Leeds Institute of Cancer and Pathology, Leeds Teaching Hospitals NHS Trust, St James's University Hospital, Beckett Street, Leeds, United Kingdom§School of Computing, University of Leeds, Leeds, United Kingdom¶School of Physics and Astronomy, University of Leeds, Leeds, United Kingdom.
    • Spine. 2015 Dec 1; 40 (24): E1315-22.

    Study DesignAn in vitro study of the intervertebral disc (IVD) structure using 9.4T magnetic resonance imaging (MRI).ObjectiveInvestigate the potential of ultrahigh-field strength MRI for higher quality 3-dimensional (3D) volumetric MRI datasets of the IVD to better distinguish structural details.Summary Of Background DataMRI has the advantages of being nondestructive and 3D in comparison to most techniques used to obtain the structural details of biological tissues, however, its poor image quality at higher resolution is a limiting factor. Ultrahigh-field MRI could improve the imaging of biological tissues but the current understanding of its application for spinal tissue is limited.Methods2 ovine spinal segments (C7-T1, T2-T3) containing the IVD were separately imaged using 2 sequences; 3D spin echo (multislice-multiecho) pulse sequence for the C7-T1 sample and 3D gradient echo (fast-low-angle-shot) pulse sequence for the T2-T3 sample. The C7-T1 sample was subsequently decalcified and imaged again using the same scanning parameters. Histological sections obtained from the decalcified sample were stained followed by digital scanning. Observations from corresponding MRI slices and histological sections were compared as a method of confirmation of morphology captured under MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative-contrast values were calculated for quantitative evaluation of image quality.ResultsMeasurements from histology sections and corresponding MRI slices matched well. Both sequences revealed finer details of the IVD structure. Under the spin echo sequence, the annulus lamellae architecture was distinguishable and the SNR and CNR values were higher. The relative contrast was considerably higher between high (nucleus) and low (bone) signal constituents, but between the nucleus and the annulus the relative contrast was low. Under the gradient echo sequence, although the relative contrasts between constituents were poor, the fiber orientation was clearly manifested.ConclusionThe obtained positive results demonstrate the potential of ultrahigh-field strength MRI to nondestructively capture the IVD structure.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.