-
Comparative Study
Evaluation of a new rapid quantitative immunoassay for serum myoglobin versus CK-MB for ruling out acute myocardial infarction in the emergency department.
- G X Brogan, S Friedman, C McCuskey, D S Cooling, L Berrutti, H C Thode, and J L Bock.
- Department of Emergency Medicine, State University of New York at Stony Brook.
- Ann Emerg Med. 1994 Oct 1; 24 (4): 665-71.
Study ObjectiveTo compare the predictive values of serum myoglobin and creatine kinase (CK)-MB for ruling out acute myocardial infarction in the emergency department.DesignProspective, observational study.SettingUniversity teaching hospital.ParticipantsOne hundred eighty nine consecutive patients aged 30 years and older who presented within 12 hours from onset of chest discomfort, dyspnea, syncope, congestive heart failure, symptomatic dysrhythmia, pulmonary edema, or epigastric pain were entered into the study. Patients with trauma or renal failure were excluded.InterventionsStandardized history and physical examination and blood sampling for serum myoglobin (S-Mgb) and CK-MB were done at the time of presentation (T0) and 1 hour later (T1).ResultsUsing World Health Organization criteria, 22 acute myocardial infarction patients were identified. Mean time from symptom onset to presentation was 3.2 hours. S-Mgb was more sensitive than CK-MB at T0 and T1, 55% versus 23% (P < .05) and 73% versus 41% (P < .05), respectively. Respective specificities of S-Mgb versus CK-MB were 98% versus 99% (P = NS) at T0 and 97% versus 99% (P = NS) at T1. Negative predictive values of S-Mgb versus CK-MB were 94% versus 91% (P = NS) at T0 and 96% versus 93% (P = NS) at T1. The S-Mgb assay yielded quantitative results allowing the difference between the T0 and T1 values to be analyzed. A difference of 40 or more ng/mL between T0 and T1 was considered positive. When using a positive result in either the T0 or T1 value or a difference between the two values of 40 or more ng/mL, the sensitivity of S-Mgb was 91% (P < .05 versus CK-MB), the specificity was 96% (P = NS versus CK-MB), and the negative predictive value was 99% (95% confidence interval for S-Mgb, 97.0 to 100 versus CK-MB, 95% confidence interval, 88.9 to 96.6).ConclusionIn the first hour of presentation to the ED, the rapid quantitative assay for S-Mgb was statistically more sensitive than CK-MB and had an excellent negative predictive value for ruling out acute myocardial infarction in patients with typical or atypical symptoms. Due to the relatively small sample size, we could not exclude the possibility that differences in specificity might become statistically significant (beta error) with a larger sample size of acute myocardial infarction patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.