Arch Orthop Trauma Surg · Apr 2021
Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study.
- Vikaesh Moorthy, Jerry Yongqiang Chen, LiowMing Han LincolnMHLDepartment of Orthopaedic Surgery, Singapore General Hospital, Block 6 Level 7, Outram Road, Singapore, 169608, Singapore., Pak Lin Chin, Shi-Lu Chia, Ngai Nung Lo, and Seng Jin Yeo.
- Yong Loo Lin School of Medicine, National University Singapore, 1E Kent Ridge Road, NUHS Tower Block, Level 11, Singapore, 119228, Singapore. vikaeshmoorthy@yahoo.com.
- Arch Orthop Trauma Surg. 2021 Apr 1; 141 (4): 669-674.
IntroductionPatient-specific instrumentation (PSI) utilizes three-dimensional imaging to produce total knee arthroplasty cutting jigs which matches patient's native anatomy. However, there are limited mid- to long-term studies examining its clinical efficacy. The aim of this study was to compare functional outcomes of PSI surgery versus conventional TKA surgery at 5-year follow-up.Materials And MethodsSixty patients were prospectively recruited into either the MRI-based PSI or conventional TKA group. Functional outcomes were assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS) and Oxford Knee Score (OKS), while quality of life was evaluated with the Physical Component Score (PCS) and Mental Component Score (MCS) of Short-Form 36 and compared between the two groups at 5-year follow-up.ResultsAlthough the PCS was 7 ± 3 points better in the PSI group preoperatively (p = 0.017), it became 5 ± 2 points worse than the conventional group at 5-year follow-up (p = 0.025). As compared to the PSI group, the conventional group showed a significantly greater improvement in PCS at 5 years as compared to before surgery (p = 0.003). There were no significant differences in KSFS, KSKS, OKS or MCS between the two groups.ConclusionsPSI TKA did not result in improved functional outcomes or better quality of life when compared to conventional TKA. The additional costs and waiting time associated with PSI are not justifiable and therefore not recommended as an alternative to conventional TKA.Level Of EvidenceII.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.