-
- Nora Di Tomasso, Caterina C Lerose, Margherita Licheri, Ligia E Alpìzar Castro, Simona Tamà, Chiara Vitiello, Giovanni Landoni, Alberto Zangrillo, and Fabrizio Monaco.
- From the Department of Anaesthesia and Intensive Care, IRCCS San Raffaele Scientific Institute (NDT, CCL, ML, ST, CV, GL, AZ, FM), Department of Anaesthesia, Mexico Hospital, San Josè, Costa Rica (LEAC) and Vita-Salute San Raffaele University, Milan, Italy (GL, AZ).
- Eur J Anaesthesiol. 2021 Apr 1; 38 (4): 402410402-410.
BackgroundOrgan perfusion is a factor of cardiac output and perfusion pressure. Recent evidence shows that dynamic arterial elastance is a reliable index of the interaction between the left ventricle and the arterial system and, in turn, of left ventricular mechanical efficiency. A practical approach to the assessment of dynamic arterial elastance at the bedside is the ratio between pulse pressure variation and stroke volume variation, which might predict the effect of a fluid challenge on the arterial pressure in patients undergoing cardiac surgery.ObjectiveTo evaluate the ability of dynamic arterial elastance, measured by the pressure recording analytical method (PRAM), to predict the response of mean arterial pressure (MAP) to a fluid challenge.DesignProspective observational study.SettingCardiac surgery patients in a university hospital.PatientsPreload-dependent (pulse pressure variation ≥13%), hypotensive (MAP ≤65 mmHg) patients, without right ventricular dysfunction, at the end of cardiac surgery.InterventionsA 250 ml fluid challenge infused over 3 min.Main Outcome MeasuresA receiver-operating characteristic curve was generated to test the ability of the baseline (before fluid challenge) dynamic arterial elastance (primary endpoint) and all other haemodynamic variables (secondary endpoint) to predict MAP responsiveness (≥10% increase in MAP) after a fluid challenge.ResultsOf 270 patients undergoing cardiac surgery, 97 (35.9%) were preload-dependent, hypotensive and received a fluid challenge. Of these 97 patients, 50 (51%) were MAP responders (≥10% increase in MAP) and 47 (48%) were MAP nonresponders (<10% increase in MAP). Baseline dynamic arterial elastance (mean ± SD) had an area under the curve of 0.64 ± 0.06 [95% confidence interval (CI), 0.53 to 0.73; P = 0.017]. A dynamic arterial elastance at least 1.07 with a grey zone ranging between 0.9 and 1.5 had 86% sensitivity (95% CI, 73 to 94) and 45% specificity (95% CI, 30 to 60) in predicting MAP increase.ConclusionIn a hypotensive preload-dependent cardiac surgery cohort without right ventricular dysfunction, dynamic arterial elastance measured by PRAM can predict pressure response for values greater than 1.5 or less than 0.9.Copyright © 2021 European Society of Anaesthesiology and Intensive Care. Unauthorized reproduction of this article is prohibited.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.