J Clin Monit Comput · Apr 2013
Comparative StudyCardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock.
- A B Johan Groeneveld, Ignacio Malagon, Cornelis Slagt, Marcel A de Leeuw, Jan Beute, Emmy Rijnsburger, Martijn Hoeksema, and Jan W R Mulder.
- Zaans Medical Centre, Koningin Julianaplein 58, Postbus 210, 1500 EE, Zaandam, The Netherlands. Slagtc@gmail.com
- J Clin Monit Comput. 2013 Apr 1;27(2):171-7.
AbstractTo evaluate the 3.02 software version of the FloTrac/Vigileo™ system for estimation of cardiac output by uncalibrated arterial pressure waveform analysis, in septic shock. Nineteen consecutive patients in septic shock were studied. FloTrac/Vigileo™ measurements (COfv) were compared with pulmonary artery catheter thermodilution-derived cardiac output (COtd). The mean cardiac output was 7.7 L min(-1) and measurements correlated at r = 0.53 (P < 0.001, n = 314). In Bland-Altman plot for repeated measurements, the bias was 1.7 L min(-1) and 95 % limits of agreement (LA) were -3.0 to 6.5 L min(-1), with a %error of 53 %. The bias of COfv inversely related to systemic vascular resistance (SVR) (r = -0.54, P < 0.001). Above a SVR of 700 dyn s cm(-5) (n = 74), bias was 0.3 L min(-1) and 95 % LA were -1.6 to 2.2 L min(-1) (%error 32 %). Changes between consecutive measurements (n = 295) correlated at 0.67 (P < 0.001), with a bias of 0.1 % (95 % limits of agreement -17.5 to 17.0 %). All changes >10 % in both COtd and COfv (n = 46) were in the same direction. Eighty-five percent of the measurements were within the 30°-330° of the polar axis. COfv with the latest software still underestimates COtd at low SVR in septic shock. The tracking capacities of the 3.02 software are moderate-good when clinically relevant changes are considered.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.