• Injury · Mar 2021

    Periosteal and endosteal microcirculatory injury following excessive osteosynthesis.

    • Ferenc Greksa, Edina Butt, Endre Csonka, Péter Jávor, Eszter Tuboly, László Török, Andrea Szabo, Endre Varga, and Petra Hartmann.
    • Department of Orthopaedics, University of Szeged, 6725 Szeged, Semmelweis u.6, Szeged, Hungary. Electronic address: dr.greksaferenc@gmail.com.
    • Injury. 2021 Mar 1; 52 Suppl 1: S3-S6.

    IntroductionWe examined the endosteal and periosteal circulations in a patient with fracture non-union who had undergone excessive osteosynthesis applications (two long plates had been placed medially and laterally on the left tibia extending from the proximal 2/7 to the distal 6/7 parts of the bone, while a tibial component of a total knee prosthesis with a long stem had been inserted at the same time).MethodsConcomitant perfusion changes were determined in the anterolateral and anteromedial periosteal sheath of the non-united bone ends and intramedullary nearest the osteosynthesis materials during their surgical removal on re-operation. The blood flow in the periosteum and endosteum was recorded by a laser-Doppler flowmetric device using a novel approach. Control measurements were made at identical points of the right tibia.ResultsConsiderably lower blood flow values were measured along the tibial periosteal region of the re-operated limb than on the contralateral side (the average perfusion unit (PU) was 76 vs. 106 PU, respectively). Perfusion values were markedly lower in the endosteal region (average values of approx. 30 PU) in the control tibia and were even more diminished in the re-operated tibial endosteum (average 9 PU).ConclusionsOur study was conducted to characterize the microcirculatory changes of a long bone in response to intramedullary implantation and to provide quantitative data on the insufficiency of local perfusion in a patient with fracture non-union. Our results highlight the association between local perfusion failure and the unfavorable outcome (i.e. fracture non-union), confirming that the vital aspects of the microcirculation should not be disregarded when aiming for mechanical stability. Microcirculatory measurements constitute a new area of improvement in planning the adequate treatment for fracture non-unions with an unclear aetiology. Further refinement of the laser-Doppler technique could have potential benefits for bone surgery and postoperative trauma care in the future.Copyright © 2020. Published by Elsevier Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…