• Radiology · Sep 2007

    Comparative Study

    Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography.

    • Anne-Catherine Pouleur, Jean-Benoît le Polain de Waroux, Agnès Pasquet, Jean-Louis J Vanoverschelde, and Bernhard L Gerber.
    • Division of Cardiology, Department of Cardiovascular Diseases, Cliniques Universitaires St Luc, Université Catholique de Louvain, Av Hippocrate 10/2806, B-1200 Woluwe St Lambert, Belgium.
    • Radiology. 2007 Sep 1; 244 (3): 745-54.

    PurposeTo prospectively compare the accuracy of multidetector computed tomographic (CT) measurements of the aortic valve area (AVA) with transesophageal echocardiography (TEE) and cine magnetic resonance (MR) measurements of this area for preoperative examination of patients undergoing cardiac surgery, with transthoracic echocardiography (TTE) as the reference standard.Materials And MethodsAfter giving informed consent for the institutional review board-approved study protocol, 48 patients (33 men, 15 women; mean age, 62 years+/-13 [standard deviation]) with (n=27) or without (n=21) aortic stenosis underwent multidetector CT, cine MR, TTE, and TEE before undergoing cardiac surgery. AVAs derived with manual planimetry by using cine short-axis multidetector CT, MR, and TEE images obtained through the aortic valve were compared among each other and with AVAs measured by using continuity equation TTE at regression and Bland-Altman analyses. The diagnostic accuracy of multidetector CT for detection of aortic stenosis was compared with that of TTE by using kappa statistics and receiver operating characteristic curves.ResultsMultidetector CT-derived AVA correlated highly with MR-derived (r=0.98, P<.001), TEE-derived (r=0.98, P<.001), and TTE-derived (r=0.96, P<.001) AVA. Multidetector CT planimetry AVAs (mean AVA+/-standard deviation, 2.5 cm2+/-1.7) were not significantly different from MR planimetry (2.4 cm2+/-1.8, P>.99) or TEE planimetery (2.5 cm2+/-1.7, P=.21) AVAs, but they were significantly larger than TTE-derived AVAs (2.0 cm2+/-1.5, P<.001). With TTE as the reference standard, multidetector CT correctly (kappa=0.88, P<.001) depicted all 21 normal, six of eight mildly stenotic (AVA>or=1.2 cm2 and <2.0 cm2), seven of eight moderately stenotic (AVA>or= 0.8 cm2 and <1.2 cm2), and 10 of 11 severely stenotic (AVA<0.8 cm2) valves. It also correctly depicted all 14 bicuspid valves identified with TEE, eight of which were missed with TTE.ConclusionMultidetector CT enables accurate noninvasive assessment of the AVA.Copyright (c) RSNA, 2007.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…