Int J Chron Obstruct Pulmon Dis · Jan 2016
Randomized Controlled Trial Comparative StudyBronchodilator efficacy of 18 μg once-daily tiotropium inhalation via Discair® versus HandiHaler® in adults with chronic obstructive pulmonary disease: randomized, active-controlled, parallel-group, open-label, Phase IV trial.
- Pinar Yildiz, Mesut Bayraktaroglu, Didem Gorgun, and Funda Secik.
- Clinics of Chest Diseases, Yedikule Chest Diseases and Thoracic Surgery Training and Research Hospital, Istanbul, Turkey.
- Int J Chron Obstruct Pulmon Dis. 2016 Jan 1; 11: 2859-2867.
PurposeTo compare the bronchodilator efficacy of 18 μg once-daily tiotropium inhalation administered via Discair® versus HandiHaler® in adults with moderate-to-severe chronic obstructive pulmonary disease (COPD).Patients And MethodsFifty-eight patients with moderate-to-severe COPD were enrolled in this randomized, active-controlled, parallel-group, open-label, Phase IV non-inferiority trial. Patients were randomly assigned to a test group (n=29, inhalation with Discair) or a reference group (n=29, inhalation with HandiHaler). The primary efficacy parameter was the average maximum change in forced expiratory volume in 1 second (FEV1, in L). Change in forced vital capacity (FVC, in L), %FEV1 and %FVC, the standardized area under the response-time curve (AUC) for the absolute change in FEV1 and FVC, time to onset and peak of response, and safety data were also evaluated.ResultsThe test inhaler was non-inferior to the reference inhaler in terms of maximum change in FEV1 at 24 h (unadjusted change: 0.0017 L [95% confidence interval [CI]: -0.0777, 0.0812]; change adjusted for time to reach maximum change in FEV1 and smoking in pack-years: 0.0116 L [95% CI: -0.0699, 0.0931]), based on a non-inferiority margin of 0.100 L. There were also no significant differences between the two groups in maximum change in FVC value from baseline (0.3417 L vs 0.4438 L, P=0.113), percent change from baseline (22.235 vs 20.783 for FEV1, P=0.662; 16.719 vs 20.337 for FVC, P=0.257), and AUC0-24 h (2.949 vs 2.833 L for FEV1, P=0.891; 2.897 vs 4.729 L for FVC, P=0.178). There were no adverse events, serious adverse events, or deaths.ConclusionOur findings show that the Discair was non-inferior to the HandiHaler. More specifically, these devices had similar clinical efficacy in terms of time-dependent response over 24 h for patients with moderate-to-severe COPD.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.