-
- Michael J DePalma, Jessica M Ketchum, Evan D Queler, and Brian S Trussell.
- VCU Spine Center, Virginia Commonwealth University Department of Physical Medicine and Rehabilitation, Richmond, VA 23235, USA. depalmamj8@yahoo.com
- PM R. 2009 Oct 1; 1 (10): 908-15.
ObjectiveTo examine changes in pain, disability, and medication usage over time from baseline to up to 12 months after facet joint injection of hylan G-F 20.DesignProspective, uncontrolled, pilot study.SettingUniversity spine center.ParticipantsFifteen patients (12 females), mean age of 57 years (standard deviation = 12.5), with a median duration of low back pain of 24 months (interquartile range = 11-66).MethodsPatients who fulfilled inclusion criteria underwent diagnostic blocks with local comparative anesthetics at one unilateral facet joint (FJ). Those with a true positive response underwent 2 1.0-mL intra-articular hylan G-F 20 injections, 10 days apart, into the painful FJ. A third hylan G-F 20 injection was offered to patients dissatisfied with the results obtained with the first 2 injections.Main Outcome MeasuresVisual analog scale (VAS) (average, standing, walking), Oswestry Disability Index (ODI), SF-36, finger to floor distance (FTF), tolerance (standing, sitting, walking), analgesic usage, and patient satisfaction collected at baseline, 7-10 days, and at 1-, 3-, 6-, and 12-months follow-up.ResultsRepeated measures mixed-models indicated that VAS (average, standing, walking [P all < .005]), ODI (P = .029), SF-36 (P = .013), FTF (P = .032), and sitting tolerance (P = .020) all showed significant changes from baseline up to 6 months and were not sustained at 12 months; with the exception of the baseline to 12-month difference for FTF. There was not evidence of changes over time in standing (P = .085) or walking (P = .084) tolerance. Satisfaction initially increased from baseline (0%) to 7-10 days (64%) but declined over time (36% at 12 months). As compared with baseline (80%), analgesic usage decreased nominally over time showing significant decreases at 6 months (33%, P = .0253) and increased slightly at 12 months (45%).ConclusionsViscosupplementation for lumbar FJ arthropathy with hylan G-F 20 is associated with modest efficacy that predominately lasts up to 6 months. Limitations include a small sample size and lack of both a control and blinding. Larger, randomized, controlled studies are indicated to better clarify its clinical safety, efficacy, and utility.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.