• Injury · Apr 2021

    Single column plate plus other column lag screw fixation vs. both column plate fixation for anterior column with posterior hemitransverse acetabular fractures - a biomechanical analysis using different loading protocols.

    • Huy Le Quang, Werner Schmoelz, Richard A Lindtner, Dietmar Dammerer, Peter Schwendinger, and Dietmar Krappinger.
    • Department of Trauma Surgery, Medical University of Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.
    • Injury. 2021 Apr 1; 52 (4): 699-704.

    ObjectivesOpen reduction and internal fixation of both columns is considered the treatment of choice for displaced anterior column with posterior hemitransverse (ACPHT) fractures in non-geriatric patients. Plate fixation of one column combined with lag screw fixation of the other column allows to decrease operative time and approach-related morbidity compared to conventional both column plating. The aim of this biomechanical study was to evaluate whether single column plate plus other column lag screw fixation confers similar stability to both column plate fixation. Physiological loads were simulated using both the single-leg stance (SLS) as well as the sit-to-stand (STS) loading protocols.MethodsA clinically relevant ACPHT fracture model was created using fourth-generation composite hemipelves. Fractures were stabilized with three different fixation constructs: (1) anterior column plate plus posterior column screw fixation (AP+PCS), posterior column plate plus anterior column screw fixation (PP+ACS) and anterior column plate plus posterior column plate fixation (AP+PP). Specimens were loaded from 50 to 750 N with a ramp of 100 N/s. Fracture gap motion (FGM) and relative interfragmentary rotation (RIFR) between the three main fracture fragments were assessed under loads of 750 N using an optical 3D measurement system.ResultsSTS loading generally resulted in higher mean FGM and RIFR than STS loading in the AP+PCS and AP+PP groups, while no significant differences were found in the PP+ACS group. Compared to conventional both column plate fixation (AP+PP), PP+ACS displayed significantly higher FGM and RIFR between the iliac wing and the posterior column during SLS loading. No significant differences in FGM and RIFR were identified between the AP+PCS and the AP+PP group.ConclusionOverall, single column plate plus other column lag screw fixation conferred similar stability to conventional both column plate fixation. From a clinical point of view, AP+PCS appears to be the most attractive alternative to conventional AP+PP for internal fixation of ACPHT fractures.Copyright © 2021. Published by Elsevier Ltd.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…