- Allison S Liang, Sean M Munier, and Shabbar F Danish.
- Department of Neurosurgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ.
- J Neuroimaging. 2021 Mar 1; 31 (2): 334-340.
Background And PurposeMagnetic resonance-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive procedure that produces real-time thermal damage estimates (TDEs) of ablation. Currently, MRgLITT software provides limited quantitative parameters for intraoperative monitoring, but orthogonal TDE-MRI slices can be utilized to mathematically estimate ablation volume. The objective of this study was to model TDE volumes and validate using post-24 hours MRI ablative volumes.MethodsAblations were performed with the Visualase Laser Ablation System (Medtronic). Using ellipsoidal parameters determined for dual-TDEs from orthogonal MRI planes, TDE volumes were calculated by two definite integral methods (A and B) implemented in Matlab (MathWorks). Post-24 hours MRI ablative volumes were measured in OsiriX (Pixmeo) by two-blinded raters and compared to TDE volumes via paired t-test and Pearson's correlations.ResultsTwenty-two ablations for 20 patients with various intracranial pathologies were included. Average TDE volume calculated with method A was 3.44 ± 1.96 cm3 and with method B was 4.83 ± 1.53 cm3 . Method A TDE volumes were significantly different than post-24 hours volumes (P < .001). Method B TDE volumes were not significantly different than post-24 hours volumes (P = .39) and strongly correlated with each other (r = .85, R2 = .72, P < .0001). A total of eight of 22 (36%) method A versus 17 of 22 (77%) method B TDE volumes were within 25% of the post-24 hours ablative volume.ConclusionWe present a viable mathematical method integrating dual-plane TDEs to calculate volumes. Future algorithmic iterations will incorporate additional calculated variables that improve ablative volume estimations.© 2021 American Society of Neuroimaging.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.