-
- Robert V O'Toole, Romney C Andersen, Oleg Vesnovsky, Melvin Alexander, L D Timmie Topoleski, Jason W Nascone, Marcus F Sciadini, Clifford Turen, and Eglseder W Andrew WA Jr.
- Department of Orthopaedics, R Adams Cowley Shock Trauma Center, University of Maryland School of Medicine, Baltimore, MD 21201, USA. rvo3@yahoo.com
- J Orthop Trauma. 2008 Nov 1; 22 (10): 709-15.
ObjectivesTo investigate whether locking screws offer any advantage over nonlocking screws for plate fixation of humeral shaft fractures for weight-bearing applications.Design: Mechanical evaluation of stiffness in torsion, bending, and axial loading and failure in axial loading in synthetic and cadaveric bone.SettingBiomechanical laboratory in an academic medical center.Methods: We modeled a comminuted midshaft humeral fracture in both synthetic and cadaveric bone. Humeri were plated posteriorly. Two study groups each used identical 10-hole, 3.5-mm locking compression plates that can accept either locking or nonlocking screws. The first group used only nonlocking screws and the second only locking screws. Stiffness testing and failure testing were performed for both the synthetic bones (n = 6) and the cadaveric matched pairs (n = 12). Fatigue testing was set at 90,000 cycles of 440 N of axial loading.Main Outcome MeasuresTorsion, bending, and axial stiffness and axial failure force after cyclic loading.ResultsWith synthetic bones, no significant difference was observed in any of the 4 tested stiffness modes between the plates with locking screws and those with nonlocking screws (anteroposterior, P = 0.51; mediolateral, P = 0.50; axial, P = 0.15; torsional, P = 0.08). With initial failure testing of the constructs in axial loading, both plates failed above anticipated physiologic loads of 440 N (mean failure load for both constructs >4200 N), but no advantage to locking screws was shown. The cadaveric portion of the study also showed no biomechanical advantage of locking screws over nonlocking screws for stiffness of the construct in the 4 tested modes (P > 0.40). Fatigue and failure testing showed that both constructs were able to withstand strenuous fatigue and to fail above anticipated loads (mean failure >3400 N). No difference in failure force was shown between the 2 groups (P = 0.67).ConclusionsSynthetic and cadaveric bone testing showed that locking screws offer no obvious biomechanical benefit in this application.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.