Journal of neurosurgery · Jul 2013
Radiation exposure in patients with subarachnoid hemorrhage: a quality improvement target.
- Judith M Wong, Allen L Ho, Ning Lin, Georgios A Zenonos, Christopher B Martel, Kai Frerichs, Rose Du, and William B Gormley.
- Department of Neurosurgery, Brigham and Women's Hospital, Boston, MA 02115, USA. jwong17@partners.org
- J. Neurosurg.. 2013 Jul 1;119(1):215-20.
ObjectThe care of patients with subarachnoid hemorrhage (SAH) has improved dramatically over the last decades. These gains are the result of improved microsurgical, endovascular, and medical management techniques. This intensive management subjects patients to multiple radiographic studies and thus increased radiation exposure. As greater understanding of the risks of radiation exposure develops, physicians must be better equipped to balance the need for optimal SAH management with the minimization of patient exposure to radiation from imaging studies. The goal in the current study was to determine if there is an opportunity for a reduction in radiation dose without a change in the quality of treatment in patients with SAH.MethodsA retrospective chart review of all patients hospitalized for SAH at the Brigham and Women's Hospital in the period from January 1, 2009, to August 31, 2010, was performed. The authors calculated cumulative and imaging study-specific radiation doses, determined the time of day that imaging studies were performed, and surveyed neurosurgeons regarding issues surrounding imaging-related radiation exposure.ResultsThe data for 77 patients were analyzed. The mean cumulative radiation dose during hospitalization was 2.76 Gy per patient (range 0.46-8.32 Gy). The mean radiation exposure from each CT, CT angiography (CTA), and angiography study was 0.08, 0.29, and 0.77 Gy (ranges 0.02-0.40, 0.15-0.99, and 0.11-4.36 Gy, respectively). Subgroup analysis of the top quartile of patients in terms of total radiation dose revealed a mean cumulative radiation dose of 4.78 Gy (range 3.42-8.32 Gy), mean cumulative number of CT and CTA scans of 14, and mean CT or CTA scan per day of 0.5 (maximum 0.8). Seventeen percent of the noncontrast head CT studies were performed just prior to morning rounds, more than double the 8% expected rate at random. Thirty-four percent of the repeat noncontrast head CTs did not show any change between scans, as documented on radiology reports. When surveyed, a majority of neurosurgeons incorrectly estimated the radiation dose typically received from CT, CTA, and angiography studies, and 65% asserted that radiation exposure is "not important" or only "somewhat important" when considering whether to order an imaging study.ConclusionsStudy findings suggested that patients with SAH have significant imaging-related exposure to radiation. The authors believe it is possible to continue the current improved outcomes in SAH with a significant reduction in radiation exposure from imaging studies. This analysis highlights the significance of accurate assessment of radiation exposure as a quality improvement target.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.