    Study DesignA prospective randomized study.ObjectiveTo compare occupational radiation exposure to the surgeon, as well as the patient, during posterior lumbar spine instrumentation in 10 navigated cases (navigated) versus 11 cases using the freehand technique (non-navigated).Summary Of Background DataThe use of navigation increases the accuracy of posterior lumbar instrumentation.A further speculated benefit of navigation is the reduction of radiation exposure of the surgeon. However, this has so far not been evaluated in such comparative manner.MethodsRadiation exposure to the surgeon was measured by digital dosimeters placed at the level of the eye, chest, and dominant forearm. Radiation exposure was measured from the time of positioning of the patient to the end of the procedure both for navigated (intraoperative 3-dimensional [3D] fluoroscopy-based) and non-navigated (2-dimensional fluoroscopy-guided) freehand posterior lumbar spine instrumentations. A 3D fluoroscopic scan was routinely performed at the end of the procedure for all patients.ResultsPatients were distributed evenly in the 2 groups in terms of sex, age, body mass index, and the number of operated levels. The accumulated radiation dose for the surgeon was significantly higher in the non-navigated group; up to 9.96 times. The radiation dose for the patient was higher with the freehand technique, 1884.8 cGy·cm (non-navigated) versus 887 cGy·cm (navigated), without reaching a statistically significant level.ConclusionRadiation exposure to the surgeon during pedicle screw placement with the freehand technique is up to 9.96 times greater than with the use of navigation. In the latter group, the only radiation exposure comes from the preoperative-level control and positioning of the 3D C-arm before 3D fluoroscopic acquisition. Furthermore, neuronavigation also reduces the cumulative dose for the patient.Level Of Evidence2.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…