• Spine · Jun 2014

    Biomechanical effects of cage positions and facet fixation on initial stability of the anterior lumbar interbody fusion motion segment.

    • Dueng-Yuan Hueng, Tzu-Tsao Chung, Wen-Hsien Chuang, Chi-Pin Hsu, Kuan-Nien Chou, and Shang-Chih Lin.
    • *Department of Neurological Surgery, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan; and †Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
    • Spine. 2014 Jun 1;39(13):E770-6.

    Study DesignAn in vitro biomechanical study using porcine lumbar segments as specimens.ObjectiveTo evaluate the effects of interbody cage support and endplate strength on the stability of instrumented segments.Summary Of Background DataThe anterior lumbar interbody fusion (ALIF) cage is widely used to restore disc height and support the anterior column. Transpedicle or posterior spinal fusion or facet screw fixation (FSF) can improve the stability of the vertebra-instrumented segments. The cage position can affect the anterior support and initial stability of the ALIF region, but there is no consistent data on its biomechanical effects on ALIF and ALIF/FSF segments.MethodsNine variations of 3 instrumentation modes (intact, ALIF, ALIF/FSF) and 3 cage positions (type I, anterolateral; type II, mediolateral; and type III, posteromedial) are tested under 5 lumbar motions. The range of motion and axial displacement are used as comparison indices for the different variations.ResultsThe cage placement serves as support for the intervertebral loads while the posterior fixation behaves as lever to further enhance the anterior support. At the endplate-cage interfaces, the endplate strength directly affects the cage subsidence. Type III exhibits higher stability for standing due to the greater strength of the endplate in the posterior region. Otherwise, type I consistently has higher stability for all other types of motion.ConclusionThe initial stability of the ALIF region is affected by the moment arm and the mechanical strength of the engaged endplates. Type I has greater moment arm and provides more efficient support to the instrumented segments. Endplate strength provides an ability to withstand lumbar loads and suppress the cage subsidence. Bone quality at the endplate-cage interfaces must therefore be cautiously evaluated preoperatively.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…