- Christina R Inscoe, Yueh Lee, Alex J Billingsley, Connor Puett, Daniel Nissman, Jianping Lu, and Otto Zhou.
- Department of Physics & Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
- Mil Med. 2021 Jan 25; 186 (Suppl 1): 745-750.
IntroductionMusculoskeletal injury to extremities is a common issue for both stateside and deployed military personnel, as well as the general public. Superposition of anatomy can make diagnosis difficult using standard clinical techniques. There is a need for increased diagnostic accuracy at the point-of-care for military personnel in both training and operational environments, as well as assessment during follow-up treatment to optimize care and expedite return to service. Orthopedic tomosynthesis is rapidly emerging as an alternative to digital radiography (DR), exhibiting an increase in sensitivity for some clinical tasks, including diagnosis and follow-up of fracture and arthritis. Commercially available digital tomosynthesis systems are large complex devices. A compact device for extremity tomosynthesis (TomoE) was previously demonstrated using carbon nanotube X-ray source array technology. The purpose of this study was to prepare and evaluate the prototype device for an Institutional Review Board-approved patient wrist imaging study and provide initial patient imaging results.Materials And MethodsA benchtop device was constructed using a carbon nanotube X-ray source array and a flat panel digital detector. Twenty-one X-ray projection images of cadaveric specimens and human subjects were acquired at incident angles from -20 to +20 degrees in various clinical orientations, with entrance dose calibrated to commercial digital tomosynthesis wrist scans. The projection images were processed with an iterative reconstruction algorithm in 1 mm slices. Reconstruction slice images were evaluated by a radiologist for feature conspicuity and diagnostic accuracy.ResultsThe TomoE image quality was found to provide more diagnostic information than DR, with reconstruction slices exhibiting delineation of joint space, visual conspicuity of trabecular bone, bone erosions, fractures, and clear depiction of normal anatomical features. The scan time was 15 seconds and the skin entrance dose was verified to be 0.2 mGy.ConclusionsThe TomoE device image quality has been evaluated using cadaveric specimens. Dose was calibrated for a patient imaging study. Initial patient images depict a high level of anatomical detail and an increase in diagnostic value compared to DR.© The Association of Military Surgeons of the United States 2021. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.