- Edward Chaum and Ernő Lindner.
- Vanderbilt University Medical Center, Department of Ophthalmology, Vanderbilt Eye Institute, Nashville, TN 37232, USA.
- Mil Med. 2021 Jan 25; 186 (Suppl 1): 370-377.
BackgroundTarget-controlled infusion anesthesia is used worldwide to provide user-defined, stable, blood concentrations of propofol for sedation and anesthesia. The drug infusion is controlled by a microprocessor that uses population-based pharmacokinetic data and patient biometrics to estimate the required infusion rate to replace losses from the blood compartment due to drug distribution and metabolism. The objective of the research was to develop and validate a method to detect and quantify propofol levels in the blood, to improve the safety of propofol use, and to demonstrate a pathway for regulatory approval for its use in the USA.MethodsWe conceptualized and prototyped a novel "smart" biosensor-enabled intravenous catheter capable of quantifying propofol at physiologic levels in the blood, in real time. The clinical embodiment of the platform is comprised of a "smart" biosensor-enabled catheter prototype, a signal generation/detection readout display, and a driving electronics software. The biosensor was validated in vitro using a variety of electrochemical methods in both static and flow systems with biofluids, including blood.ResultsWe present data demonstrating the experimental detection and quantification of propofol at sub-micromolar concentrations using this biosensor and method. Detection of the drug is rapid and stable with negligible biofouling due to the sensor coating. It shows a linear correlation with mass spectroscopy methods. An intuitive graphical user interface was developed to: (1) detect and quantify the propofol sensor signal, (2) determine the difference between targeted and actual propofol concentration, (3) communicate the variance in real time, and (4) use the output of the controller to drive drug delivery from an in-line syringe pump. The automated delivery and maintenance of propofol levels was demonstrated in a modeled benchtop "patient" applying the known pharmacokinetics of the drug using published algorithms.ConclusionsWe present a proof-of-concept and in vitro validation of accurate electrochemical quantification of propofol directly from the blood and the design and prototyping of a "smart," indwelling, biosensor-enabled catheter and demonstrate feedback hardware and software architecture permitting accurate measurement of propofol in blood in real time. The controller platform is shown to permit autonomous, "closed-loop" delivery of the drug and maintenance of user-defined propofol levels in a dynamic flow model.© The Association of Military Surgeons of the United States 2021. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.