    Comparative Study

    Kinematic and mechanical comparisons of lumbar hybrid fixation using Dynesys and Cosmic systems.

    • Chen-Ying Chien, Yi-Jie Kuo, Shang-Chih Lin, Wen-Hsien Chuang, and Yuan-Ping Luh.
    • *Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan †Department of Orthopaedics, Taipei Medical University Hospital, Taipei, Taiwan; and ‡Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
    • Spine. 2014 Jul 1;39(15):E878-84.

    Study DesignThe biomechanical effects of Dynesys and Cosmic fixators on transition and adjacent segments were evaluated using the finite-element method.ObjectiveThis study investigated the load-transferring mechanisms of 2 dynamic fixators and the fixator-induced effects on the junctional problem of the adjacent segments.Summary Of Background DataThe mobility and flexibility of Dynesys screw-spacer and Cosmic screw-hinge joints preserve motion and share loads for the transition segment. However, the differences in tissue responses and fixator mechanisms among these 2 fixators have not been investigated extensively.MethodsA lumbosacral model from L1 to S1 levels was developed and subjected to muscular contraction, ligamentous interconnection, compressive force, and trunk moment. A static fixator was instrumented at the moderately degenerative L4-L5 segment to serve as a comparison baseline. Subsequently, the 2 fixators were instrumented at the mildly degenerative L3-L4 segment. The tissue responses of the adjacent segments and the load transmission at the screw-spacer and bone-screw interfaces were compared.ResultsBoth systems show the ability to protect the transition segment but deteriorate the adjacent segments. The screw-hinge joint and the stiffer rod of the Cosmic system significantly constrained the motion pattern of the transition segment. Comparatively, the Dynesys screw-spacer interfaces make contact with and depart from each other during motion; thus providing higher mobility to the transition segment. However, the highly stressed distribution at the Cosmic bone-screw causes the screw and hinge prone to pullout and fatigue failures.ConclusionCosmic fixation can better protect the disc and facet joint of the transition segment than can the Dynesys. However, the screw-hinge joint strictly constrains intersegmental motion and deteriorates the junctional problem. The Cosmic system can be chosen to treat more severely degenerative transition segments. With higher flexibility, the Dynesys system is recommended for the transition segment that is healthy or mildly degenerative.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…