J Clin Monit Comput · Dec 2013
Comparative Study Clinical TrialCardiac index assessment using bioreactance in patients undergoing cytoreductive surgery in ovarian carcinoma.
- David Kober, Constantin Trepte, Martin Petzoldt, Rainer Nitzschke, Lena Herich, Daniel A Reuter, and Sebastian Haas.
- Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
- J Clin Monit Comput. 2013 Dec 1;27(6):621-7.
AbstractThis clinical study compared the cardiac index (CI) assessed by the totally non-invasive method of bioreactance (CIBR) (NICOM™, Cheetah Medical, Vancouver, USA) to transpulmonary thermodilution (CITD) during cytoreductive surgery in ovarian carcinoma. The hypothesis was that CI could be assessed by bioreactance in an accurate and precise manner including accurate trending ability when compared to transpulmonary thermodilution. In 15 patients CIBR and CITD were assessed after induction of anesthesia, after opening of the peritoneum, hourly during the operative procedure, and 30 min after extubation. Trending ability was assessed between the described timepoints. In total 84 points of measurement were analyzed. Concordance correlation coefficient for repeated measures correlating the CIBR and CITD was 0.32. Bias was 0.26 l/min/m(2) (limits of agreement -1.39 and 1.92 l/min/m(2)). The percentage error was 50.7 %. Trending ability quantified by the mean of angles θ which are made by the ΔCI vector and the line of identity (y = x) showed a value for CIBR of θ = 23.4°. CI assessment by bioreactance showed acceptable accuracy and trending ability. However, its precision was poor. Therefore, CI measurement can not be solely based on bioreactance in patients undergoing cytoreductive surgery in ovarian carcinoma.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.