• Acta Neurochir. Suppl. · Jan 2018

    Medical Waveform Format Encoding Rules Representation of Neurointensive Care Waveform Data.

    • Ian Piper, Martin Shaw, Christopher Hawthorne, John Kinsella, and Laura Moss.
    • Department of Clinical Physics and Bioengineering, Institute of Neurological Sciences, NHS Greater Glasgow and Clyde, Queen Elizabeth University Hospital, Glasgow, UK. ian.piper@brainit.org.
    • Acta Neurochir. Suppl. 2018 Jan 1; 126: 183-188.

    ObjectiveTechnology in neurointensive care units can collect and store vast amounts of complex patient data. The CHART-ADAPT project is aimed at developing technology that will allow for the collection, analysis and use of these big data at the patient's bedside in neurointensive care units. A requirement of this project is to automatically extract and transfer high-frequency waveform data (e.g. ICP) from monitoring equipment to high performance computing infrastructure for analysis. Currently, no agreed data standard exists in neurointensive care for the description of this type of data. In this pilot study, we investigated the use of Medical Waveform Format Encoding Rules (MFER- www.mfer.org-ISO 11073-92001) as a possible data standard for neurointensive care waveform data.Materials And MethodsSeveral waveform formats were explored (e.g. XML, DICOM waveform) and evaluated for suitability given existing computing infrastructure constraints, e.g. NHS network capacity and the processing capabilities of existing integration software. Key requirements of the format included a compact data size and the use of a recognised standard. The MFER waveform format (ISO/TS 11073-92001) met both requirements. To evaluate the practicality of the MFER waveform format, seven waveform signals (ICP, ECG, ART, CVP, EtCO2, Pleth, Resp) collected over a period of 8 h from a patient at the Institute of Neurological Sciences in Glasgow were converted into MFER waveform format.ResultsThe MFER waveform format has two main components: sampling information and frame information. Sampling information describes the frequency of the data sampling and the resolution of the data. Frame information describes the data itself; it consists of three elements: data block (the actual data), channel (each type of waveform data occupies a channel) and sequence (the repetition of the data). All seven waveform signals were automatically and successfully converted into the MFER waveform format. One MFER file was created for each minute of data (total of 479 files, 181 KB each).ConclusionsThe MFER waveform format has potential as a lightweight standard for representing high-frequency neurointensive care waveform data. Further work will include a comparison with other waveform data formats and a live trial of using the MFER waveform format to stream patient data over a longer period.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.