• J Spinal Disord Tech · Aug 2010

    A computer-aided Cobb angle measurement method and its reliability.

    • Junhua Zhang, Edmond Lou, Xinling Shi, Yuanyuan Wang, Douglas L Hill, James V Raso, Lawrence H Le, and Liang Lv.
    • Department of Electronic Engineering, Yunnan University, Yunnan, China. jhzhang_2006@yahoo.com.cn
    • J Spinal Disord Tech. 2010 Aug 1; 23 (6): 383-7.

    Study DesignDevelopment of a computer-aided Cobb measurement method and evaluation of its reliability.ObjectivesTo reduce the variability of Cobb angle measurement by developing the computer-aided method and to investigate if the developed method is sensitive to observer skill levels or experiences.Summary Of Background DataTherapeutic decisions for scoliosis heavily rely on the Cobb angle measured from consecutive radiographs. The manual Cobb measurement is subject to human errors. The observer error is 3 to 10 degrees resulted from different end-vertebrae selection and/or manually drawing variable best-fit lines to the endplates of the end-vertebrae.MethodsA fussy Hough transform technique was used to develop a computer-aided method to detect the vertebral endplates. The Cobb angle, upper end-vertebra, and lower end-vertebra were then measured automatically. The computer-aided method was tested twice by each of 3 observers in 84 posteroanterior radiographs from patients with adolescent idiopathic scoliosis. The intraobserver and interobserver errors were analyzed.ResultsBoth the intraobserver and interobserver reliability analyses resulted in the intraclass correlation coefficients higher than 0.9 for the Cobb angle. The average intraobserver and interobserver errors were less than 3 degree for the Cobb angle, and less than 0.3 levels for both the upper and lower end-vertebral identification. There were no significant differences in the measurement variability between groups of curve location (thoracic, thoracolumbar, and lumbar), curve direction (right and left), curve magnitude (curves less than 25 degree, between 25 and 45 degrees, and more than 45 degree), and observer experience (experienced observer and inexperienced observers).ConclusionsCompared with the documented results, variability of the Cobb measurement is reduced by using the developed computer-aided method. This method can help orthopedic surgeons measure the Cobb angle more reliably during scoliosis clinics.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…