    The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.

    • Yohei Sotomi, Katsuomi Iwakura, Yoshiharu Higuchi, Kazuo Abe, Junko Yoshida, Takafumi Masai, and Kenshi Fujii.
    • Cardiovascular Center, Sakurabashi-Watanabe Hospital, 2-4-32 Umeda, Kita-ku, Osaka, 530-0001, Japan, sotomiyohei@yahoo.co.jp.
    • J Clin Monit Comput. 2013 Dec 1;27(6):639-46.

    AbstractFloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients in the perioperative period of cardiac surgery with FloTrac/Vigileo™ system (v. 3.02) and Swan-Ganz catheter/Vigilance™ system pulmonary artery catheter-based CO (PAC-CO) simultaneously. Continuous hemodynamic measurement using both methods was performed every 20 s from the induction of anesthesia to PAC removal 4 h after extubation. A total of 11,092 (intraoperative), 38,455 (postoperative, pre-extubation), and 44,235 (postoperative, post-extubation) data pairs were finally analyzed. Bland-Altman analysis revealed that in the intraoperative [postoperative pre-extubation, post-extubation] period, the bias was 0.5 [0.1, 0.0] L/min and the limits of agreement ranged from -2.4 to 3.3 [-2.2 to 2.4, -2.4 to 2.3] L/min. The percentage error was 60.3 [54.5, 48.5] %. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between APCO and PAC-CO showed that the bias was positively correlated to the SVRI. Subanalysis based on SVR with Lin's concordance correlation coefficient revealed that relatively satisfactory concordance was found in the normal-SVR group (concordance correlation coefficient ρ c = 0.51-0.56) regardless of vasoactive agent use. The accuracy of the FloTrac/Vigileo™ System (v. 3.02) is relatively satisfactory in the condition with normal SVR regardless of vasoactive agent use. Positive correlation between the bias and SVR can be the clue to the more effective use of FloTrac/Vigileo™ system.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.