Journal of neurosurgery · Dec 2013
Assessment of intracranial dynamics in hydrocephalus: effects of viscoelasticity on the outcome of infusion tests.
- Simone Bottan, Marianne Schmid Daners, Diane de Zelicourt, Norina Fellner, Dimos Poulikakos, and Vartan Kurtcuoglu.
- Laboratory of Thermodynamics in Emerging Technologies;
- J. Neurosurg.. 2013 Dec 1;119(6):1511-9.
ObjectThe treatment of hydrocephalus requires insight into the intracranial dynamics in the patient. Resistance to CSF outflow (R0) is a clinically obtainable parameter of intracranial fluid dynamics that quantifies the apparent resistance to CSF absorption. It is used as a criterion for the selection of shunt candidates and serves as an indicator of shunt performance. The R0 is obtained clinically by performing 1 of 3 infusion tests: constant flow, constant pressure, or bolus infusion. Among these, the bolus infusion method has the shortest examination times and provides the shortest time of exposure of patients to artificially increased intracranial pressure (ICP) levels. However, for unknown reasons, the bolus infusion method systematically underestimates the R0. Here, the authors have tested and verified the hypothesis that this underestimation is due to lack of accounting for viscoelasticity of the craniospinal space in the calculation of the R0.MethodsThe authors developed a phantom model of the human craniospinal space in order to reproduce in vivo pressure-volume (PV) relationships during infusion testing. The phantom model followed the Marmarou exponential PV equation and also included a viscoelastic response to volume changes. Parameters of intracranial fluid dynamics, such as the R0, could be controlled and set independently. In addition to the phantom model, the authors designed a computational framework for virtual infusion testing in which viscoelasticity can be turned on or off in a controlled manner. Constant flow, constant pressure, and bolus infusion tests were performed on the phantom model, as well as on the virtual computational platform, using standard clinical protocols. Values for the R0 were derived from each infusion test by using both a standard method based on the Marmarou PV equation and a novel method based on a system identification approach that takes into account viscoelastic behavior.ResultsExperiments with the phantom model confirmed clinical observations that both the constant flow and constant pressure infusion tests, but not the bolus infusion test, yield correct R0 values when they are determined with the standard method according to Marmarou. Equivalent results were obtained using the computational framework. When the novel system identification approach was used to determine the R0, all of the 3 infusion tests yielded correct values for the R0. CONCLUSIONS" The authors' investigations demonstrate that intracranial dynamics have a substantial viscoelastic component. When this viscoelastic component is taken into account in calculations, the R0, is no longer underestimated in the bolus infusion test.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.