-
J. Am. Coll. Cardiol. · Sep 2010
The value of defibrillator electrograms for recognition of clinical ventricular tachycardias and for pace mapping of post-infarction ventricular tachycardia.
- Kentaro Yoshida, Tzu-Yu Liu, Clayton Scott, Alfred Hero, Miki Yokokawa, Sanjaya Gupta, Eric Good, Fred Morady, and Frank Bogun.
- Division of Cardiovascular Medicine, University of Michigan, Ann Arbor, Michigan, USA.
- J. Am. Coll. Cardiol. 2010 Sep 14; 56 (12): 969-79.
ObjectivesThe purpose of this study was to assess the value of implantable cardioverter-defibrillator (ICD) electrograms (EGMs) in identifying clinically documented ventricular tachycardias (VTs).BackgroundTwelve-lead electrocardiograms (ECG) of spontaneous VT often are not available in patients referred for catheter ablation of post-infarction VT. Many of these patients have ICDs, and the ability of ICD EGMs to identify a specific configuration of VT has not been described.MethodsIn 21 consecutive patients referred for catheter ablation of post-infarction VT, 124 VTs (mean cycle length: 393 ± 103 ms) were induced, and ICD EGMs were recorded during VT. Clinical VT had been documented with 12-lead ECGs in 15 of 21 patients. The 12-lead ECGs of the clinical VTs were compared with 64 different inducible VTs (mean cycle length: 390 ± 91 ms) to assess how well the ICD EGMs differentiated the clinical VTs from the other induced VTs. The exit site of 62 VTs (mean cycle length: 408 ± 112 ms) was identified by pace mapping (10 to 12 of 12 matching leads). The spatial resolution of pace mapping to identify a VT exit site was determined for both the 12-lead ECGs and the ICD EGMs using a customized MATLAB program (version 7.5, The MathWorks, Inc., Natick, Massachusetts).ResultsAnalysis of stored EGMs by comparison of receiver-operating characteristic curve cutoff values accurately distinguished the clinical VTs from 98% of the other inducible VTs. The mean spatial resolution of a 12-lead ECG pace map for the VT exit site was 2.9 ± 4.0 cm(2) (range 0 to 17.5 cm(2)) compared with 8.9 ± 9.0 cm(2) (range 0 to 35 cm(2)) for ICD EGM pace maps. The spatial resolution of pace mapping varied greatly between patients and between VTs. The spatial resolution of ICD EGMs was < 1.0 cm(2) for ≥ 1 of the target VTs in 12 of 21 patients and 19 of 62 VTs. By visual inspection of the ICD EGMs, 96% of the clinical VTs were accurately differentiated from previously undocumented VTs.ConclusionsStored ICD EGMs usually are an accurate surrogate for 12-lead ECGs for differentiating clinical VTs from other VTs. Pace mapping based on ICD EGMs has variable resolution but may be useful for identifying a VT exit site.Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.