• Journal of neurosurgery · Jan 2014

    Risks of common complications in deep brain stimulation surgery: management and avoidance.

    • Albert J Fenoy and Richard K Simpson.
    • Mischer Neuroscience Institute, Department of Neurosurgery, The University of Texas Health Science Center at Houston; and.
    • J. Neurosurg. 2014 Jan 1; 120 (1): 132-9.

    ObjectDeep brain stimulation (DBS) surgery is increasingly prominent in the treatment of various disorders refractory to medication. Despite the procedure's efficacy, the community at large continues to be hesitant about presumed associated risks. The main object of this study was to assess the incidence of various surgical complications occurring both during and after DBS device implantation in a large population of patients with movement disorders in an effort to better quantify patient risk, define management plans, and develop methods for risk avoidance. A second aim was to corroborate the low procedural complication risk of DBS reported by others, which in light of the procedure's efficacy is needed to promote its widespread acceptance.MethodsAll patients who had undergone new DBS device implantation surgery between 2002 and 2010 by a single surgeon were entered into a database after being verified by cross-referencing manufacturer implantation records. All surgical records and charts were reviewed to identify intraoperative, perioperative, and long-term surgical complications, including any characteristics predictive of an adverse event.ResultsSeven hundred twenty-eight patients received 1333 new DBS electrodes and 1218 new internal pulse generators (IPGs) in a total of 1356 stereotactic procedures for the treatment of movement disorders. Seventy-eight percent of the patients had staged lead and IPG implantations. Of the 728 patients, 452 suffered from medically refractory Parkinson disease; in the other patients, essential tremor (144), dystonia (64), mixed disease (30), and other hyperkinetic movement disorders (38) were diagnosed. Severe intraoperative adverse events included vasovagal response in 6 patients (0.8%), hypotension in 2 (0.3%), and seizure in 2 (0.3%). Postoperative imaging confirmed asymptomatic intracerebral hemorrhage (ICH) in 4 patients (0.5%), asymptomatic intraventricular hemorrhage in 25 (3.4%), symptomatic ICH in 8 (1.1%), and ischemic infarction in 3 (0.4%), associated with hemiparesis and/or decreased consciousness in 13 (1.7%). Long-term complications of DBS device implantation not requiring additional surgery included hardware discomfort in 8 patients (1.1%) and loss of desired effect in 10 (1.4%). Hardware-related complications requiring surgical revision included wound infections in 13 patients (1.7%), lead malposition and/or migration in 13 (1.7%), component fracture in 10 (1.4%), component malfunction in 4 (0.5%), and loss of effect in 19 (2.6%).ConclusionsThe authors confirmed that the overall risk of both procedure- and hardware-related adverse events is acceptably low. They offer advice on how to avoid the most common complications.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…