Int J Comput Assist Radiol Surg · Nov 2020
Randomized Controlled TrialUltrasound in augmented reality: a mixed-methods evaluation of head-mounted displays in image-guided interventions.
- Christoph Rüger, Markus A Feufel, Simon Moosburner, Christopher Özbek, Johann Pratschke, and Igor M Sauer.
- Department of Surgery, Campus Charité Mitte | Campus Virchow-Klinikum, Experimental Surgery, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Augustenburger Platz 1, 13353, Berlin, Germany.
- Int J Comput Assist Radiol Surg. 2020 Nov 1; 15 (11): 1895-1905.
PurposeAugmented reality (AR) and head-mounted displays (HMD) in medical practice are current research topics. A commonly proposed use case of AR-HMDs is to display data in image-guided interventions. Although technical feasibility has been thoroughly shown, effects of AR-HMDs on interventions are not yet well researched, hampering clinical applicability. Therefore, the goal of this study is to better understand the benefits and limitations of this technology in ultrasound-guided interventions.MethodsWe used an AR-HMD system (based on the first-generation Microsoft Hololens) which overlays live ultrasound images spatially correctly at the location of the ultrasound transducer. We chose ultrasound-guided needle placements as a representative task for image-guided interventions. To examine the effects of the AR-HMD, we used mixed methods and conducted two studies in a lab setting: (1) In a randomized crossover study, we asked participants to place needles into a training model and evaluated task duration and accuracy with the AR-HMD as compared to the standard procedure without visual overlay and (2) in a qualitative study, we analyzed the user experience with AR-HMD using think-aloud protocols during ultrasound examinations and semi-structured interviews after the task.ResultsParticipants (n = 20) placed needles more accurately (mean error of 7.4 mm vs. 4.9 mm, p = 0.022) but not significantly faster (mean task duration of 74.4 s vs. 66.4 s, p = 0.211) with the AR-HMD. All participants in the qualitative study (n = 6) reported limitations of and unfamiliarity with the AR-HMD, yet all but one also clearly noted benefits and/or that they would like to test the technology in practice.ConclusionWe present additional, though still preliminary, evidence that AR-HMDs provide benefits in image-guided procedures. Our data also contribute insights into potential causes underlying the benefits, such as improved spatial perception. Still, more comprehensive studies are needed to ascertain benefits for clinical applications and to clarify mechanisms underlying these benefits.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.