• Spine · Sep 2014

    Case Reports

    Fatal intraoperative cardiac arrest after application of surgifoam into a bleeding iliac screw defect.

    • Branko Skovrlj, Soriaya Motivala, Fedor Panov, Jeremy Steinberger, Jeremy Stuelpnagel, Samuel K Cho, and John Caridi.
    • *Department of Neurosurgery, Icahn School of Medicine at Mount Sinai, New York, NY †Office of the Chief Medical Examiner of the City of New York, New York, NY; and ‡Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY.
    • Spine. 2014 Sep 15; 39 (20): E1239-42.

    Study DesignCase report.ObjectiveTo describe the presentation, management, and autopsy findings in a case of a fatal intraoperative cardiac arrest after application of an absorbable hemostatic agent into a bleeding iliac bone screw defect.Summary Of Background DataTo the authors' knowledge, this represents the first reported complication of intraoperative death associated with Surgifoam (Ethicon) thromboembolization to the heart and lung microcirculation after its application into a bleeding bone defect.MethodsA 56-year-old male was undergoing revision fusion surgery for pseudarthrosis after multilevel thoracolumbosacral fusion with pelvic fixation for degenerative scoliosis. Intraoperatively, upon removal of the right iliac screw, heavy venous bleeding was encountered, which was stopped after application of 10 mL of Surgifoam into the screw defect. Approximately 5 minutes later, the patient's end tidal CO2 dropped, and his pulse was lost. Epinephrine was administered and the patient was immediately turned to supine position and cardiopulmonary resuscitation initiated. Cardiopulmonary resuscitation was performed unsuccessfully for 30 minutes at the end of which the patient was pronounced dead.ResultsAutopsy findings revealed angulated particles of hemostatic agent with entrapped red blood cells partially to completely occluding small-to-medium-sized vessels of the heart and lungs. The cause of death was pulmonary and cardiac embolization of foreign material from the surgical screw defect to the vessels of the heart and lungs, significantly compromising respiration and blood flow causing sudden death.ConclusionAlthough Surgifoam is an excellent hemostatic agent for use in spinal surgery, it must be used with extreme caution in the setting of heavily bleeding bone defects after pedicle cannulation or removal of instrumentation. In cases when brisk venous bleeding is encountered, signifying potential compromise of an emissary vein, use of other hemostatic agents such as bone wax may be a safer option.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.