    Postimplantation MRI with cylindric and cubic intervertebral test implants: evaluation of implant shape, material, and volume in MRI artifacting--an in vitro study.

    • Thorsten Ernstberger, Gabert Heidrich, and Gottfried Buchhorn.
    • Department of Orthopedic Surgery, University of Gottingen, Robert-Koch-Strasse 40, 37075 Gottingen, Germany. ternstberger@med.uni-goettingen.de
    • Spine J. 2007 May 1; 7 (3): 353-9.

    Background ContextInterbody spacers for anterior spine fusion are made of different materials, which can affect the postfusion magnetic resonance imaging (MRI) scans. Susceptibility artifacts specially for metallic implants can decrease the image quality.PurposeThis study focused on the influence of determined implant parameters like shape, implant volume, and implant material in MRI artifacting with regard to solid geometrical titanium and carbon test spacers.Study Design/SettingA comparative study on an in vitro spine model. The study was performed at a university research facility.MethodsIn this study we evaluated the postimplantation MRI scans of three determined cuboids and six cylinders, which were made of titanium alloy and carbon fiber reinforced polymer. MRI scans were carried out by using T1 turbo spin echo (TSE) sequences. The total artifact volume (TAV) as well as median artifact area (MAA) were calculated. Additionally the implant volume (IV)/TAV and cross-sectional area (CSA)/MAA relation were determined. Statistical analyses were calculated with the t test and Newman-Keuls test for multiple comparisons.ResultsConsidering all test implants with an increasing implant size, the TAV and the MAA became significantly larger (p<.001) with simultaneous reduction of the IV/TAV and CSA/MAA relation. In contrast to the carbon implant group, for titanium cylinders with an implant volume equivalent to the cuboids significant differences in MRI artifacting (p<.05) could be demonstrated.ConclusionsSusceptibility artifacts were clearly affected by the implant material, shape, and implant volume. Independent of the implant material, with regard to a more advantageous IV/TAV and CSA/MAA relation, for larger implants the artifact rate was more limited to the implant's direct surroundings. On the basis of a high magnetizability for titanium implants with an equal IV, the range of implant-related susceptibility artifacts was influenced by the material as well as implant shape in favor of cylindric implants. According to the very low MRI artifact rate of carbon implants, the implant shape did not have any significant effect on the artifact behavior.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.