• Pacing Clin Electrophysiol · Feb 2009

    Determinants of lesion dimensions during transcatheter microwave ablation.

    • Hung-Fat Tse, Songyan Liao, Chung-Wah Siu, Liu Yuan, John Nicholls, George Leung, Ted Ormsby, Gregory K Feld, and Chu-Pak Lau.
    • Department of Medicine, Cardiology Division, University of Hong Kong, Hong Kong, China. hftse@hkucc.hku.hk
    • Pacing Clin Electrophysiol. 2009 Feb 1; 32 (2): 201-8.

    BackgroundTranscatheter microwave ablation is a novel technique for treating cardiac arrhythmias.MethodsWe investigated the effects of catheter temperature, application duration, and antenna length on lesion dimensions during catheter-based microwave ablation. In a swine thigh muscle preparation, microwave was delivered at targeted temperatures of 60 degrees C (n = 18), 70 degrees C (n = 27), 80 degrees C (n = 43), or 90 degrees C (n = 18) for 120 seconds with 10-mm antenna; and at targeted temperatures of 80 degrees C for 120 seconds (n = 22), 150 seconds (n = 18), 180 seconds (n = 18), 210 seconds (n = 18), and 240 seconds (n = 17) with 20-mm antenna using 10 F catheter (MedWaves, San Diego, CA, USA) during parallel orientation. Conventional radiofrequency ablation (RF) using a 4-mm tip electrode was performed as control.ResultsWith 120-second energy applications, lesion length and depth were significantly larger with targeted temperatures of 80 degrees C and 90 degrees C than 60 degrees C (P< 0.05). Furthermore, lesion depth and width, but not length, were significantly increased by prolonging energy application duration from 120 to 240 seconds at targeted temperature of 80 degrees C (P< 0.05). Compared to RF, microwave lesions were significantly longer but had comparable depth and width. A 20-mm microwave antenna produced longer lesions than either a 10-mm antenna or RF ablation catheter. Multivariate analysis demonstrated that targeted temperature >or=80 degrees C, application duration >or=150 seconds, and use of 20-mm antenna were independent predictors for lesion depth and width (P< 0.05). Surface dessication was observed in 4/18 (22%) lesions at 90 degrees C, as compared with 1/136 (0.7%) at 80 degrees C targeted tip temperature (P < 0.05).ConclusionsThis study demonstrated that lesions size with transcatheter microwave ablation can be controlled by adjusting targeted temperature, energy application duration, and antenna length. A targeted temperature of 80 degrees C for more than 150 seconds should provide optimal lesion dimensions and lower risk of surface dessication or charring.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…