• Ann Am Thorac Soc · Mar 2021

    Clinical Trial

    Mandibular Advancement Device Treatment Efficacy is Associated with Polysomnographic Endotypes.

    • Sara Op de Beeck, Marijke Dieltjens, Ali Azarbarzin, Marc Willemen, Johan Verbraecken, Marc J Braem, Andrew Wellman, Scott A Sands, and Olivier M Vanderveken.
    • Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium.
    • Ann Am Thorac Soc. 2021 Mar 1; 18 (3): 511-518.

    AbstractRationale: Mandibular advancement device (MAD) treatment efficacy varies among patients with obstructive sleep apnea.Objectives: The current study aims to explain underlying individual differences in efficacy using obstructive sleep apnea endotypic traits calculated from baseline clinical polysomnography: collapsibility (airflow at normal ventilatory drive), loop gain (drive response to reduced airflow), arousal threshold (drive preceding arousal), compensation (increase in airflow as drive increases), and the ventilatory response to arousal (increase in drive explained by arousal). On the basis of previous research, we hypothesized that responders to MAD treatment have a lower loop gain and milder collapsibility.Methods: Thirty-six patients (median apnea-hypopnea index [AHI], 23.5 [interquartile range (IQR), 19.7-29.8] events/h) underwent baseline and 3-month follow-up full polysomnography, with MAD fixed at 75% of maximal protrusion. Traits were estimated using baseline polysomnography according to Sands and colleagues. Response was defined as an AHI reduction ≥ 50%.Results: MAD treatment significantly reduced AHI (49.7%baseline [23.9-63.6], median [IQR]). Responders exhibited lower loop gain (mean [95% confidence interval], 0.53 [0.48-0.58] vs. 0.65 [0.57-0.73]; P = 0.020) at baseline than nonresponders, a difference that persisted after adjustment for baseline AHI and body mass index. Elevated loop gain remained associated with nonresponse after adjustment for collapsibility (odds ratio, 3.03 [1.16-7.88] per 1-standard deviation (SD) increase in loop gain [SD, 0.15]; P = 0.023).Conclusions: MAD nonresponders exhibit greater ventilatory instability, expressed as higher loop gain. Assessment of the baseline degree of ventilatory instability using this approach may improve upfront MAD treatment patient selection.Clinical trial registered with www.clinicaltrials.gov (NCT01532050).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.