Journal of patient safety · Mar 2020
Development of an Emergency Department Trigger Tool Using a Systematic Search and Modified Delphi Process.
- Richard Thomas Griffey, Ryan M Schneider, Lee M Adler, Roberta Capp, Christopher R Carpenter, Brenna M Farmer, Kathyrn Y Groner, Sheridan Hodkins, Craig A McCammon, Jonathan T Powell, Jonathan E Sather, Jeremiah D Schuur, Marc J Shapiro, Brian R Sharp, Arjun K Venkatesh, Marie C Vrablik, and Jennifer L Wiler.
- From the Division of Emergency Medicine, Washington University School of Medicine, St. Louis, Missouri.
- J Patient Saf. 2020 Mar 1; 16 (1): e11-e17.
ObjectiveThis study aimed to develop an emergency department (ED) trigger tool to improve the identification of adverse events in the ED and that can be used to direct patient safety and quality improvement. This work describes the first step toward the development of an ED all-cause harm measurement tool by experts in the field.MethodsWe identified a multidisciplinary group of emergency medicine safety experts from whom we solicited candidate triggers. We then conducted a modified Delphi process consisting of 4 stages as follows: (1) a systematic literature search and review, including an independent oversampling of review for inclusion, (2) solicitation of empiric triggers from participants, (3) a Web-based survey ranking triggers on specific performance constructs, and (4) a final in-person meeting to arrive at consensus triggers for testing. Results of each step were shared with participants between each stage.ResultsAmong an initial 804 unique articles found using our search criteria, we identified 94 that were suitable for further review. Interrater reliability was high (κ = 0.80). Review of these articles yielded 56 candidate triggers. These were supplemented by 58 participant-submitted triggers yielding a total of 114 candidate triggers that were shared with team members electronically along with their definitions. Team members then voted on each measure via a Web-based survey, ranking triggers on their face validity, utility for quality improvement, and fidelity (sensitivity/specificity). Participants were also provided the ability to flag any trigger about which they had questions or they felt merited further discussion at the in-person meeting. Triggers were ranked by combining the first 2 categories (face validity and utility), and information on fidelity was reviewed for decision making at the in-person meeting. Seven redundant triggers were eliminated. At an in-person meeting including representatives from all facilities, we presented the 50 top-ranked triggers as well as those that were flagged on the survey by 2 or more participants. We reviewed each trigger individually, identifying 41 triggers about which there was a clear agreement for inclusion. Of the seven additional triggers that required subsequent voting via e-mail, 5 were adopted, arriving at a total of 46 consensus-derived triggers.ConclusionsOur modified Delphi process resulted in the identification of 46 final triggers for the detection of adverse events among ED patients. These triggers should be pilot field tested to quantify their individual and collective performance in detecting all-cause harm to ED patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.