• Eur Spine J · Mar 2017

    Rotation effect and anatomic landmark accuracy for midline placement of lumbar artificial disc under fluoroscopy.

    • Mark Mikhael, Jaysson T Brooks, Yusuf T Akpolat, and Wayne K Cheng.
    • Department of Orthopaedic Surgery, School of Medicine, Loma Linda University, 11406 Loma Linda Dr, Suite 213, Loma Linda, CA, 92354, USA.
    • Eur Spine J. 2017 Mar 1; 26 (3): 794-798.

    PurposeTotal disc arthroplasty can be a viable alternative to fusion for degenerative disc disease of the lumbar spine. The correct placement of the prosthesis within 3 mm from midline is critical for optimal function. Intra-operative radiographic error could lead to malposition of the prosthesis. The objective of this study was first to measure the effect of fluoroscopy angle on the placement of prosthesis under fluoroscopy. Secondly, determine the visual accuracy of the placement of artificial discs using different anatomical landmarks (pedicle, waist, endplate, spinous process) under fluoroscopy.MethodsArtificial discs were implanted into three cadaver specimens at L2-3, L3-4, and L4-L5. Fluoroscopic images were obtained at 0°, 2.5°, 5°, 7.5°, 10°, and 15° from the mid axis. Computerized tomography (CT) scans were obtained after the procedure. Distances were measured from each of the anatomic landmarks to the center of the implant on both fluoroscopy and CT. The difference between fluoroscopy and CT scans was compared to evaluate the position of prosthesis to each anatomic landmark at different angles.ResultsThe differences between the fluoroscopy to CT measurements from the implant to pedicle was 1.31 mm, p < 0.01; implant to waist was 1.72 mm, p < 0.01; implant to endplate was 1.99 mm, p < 0.01; implant to spinous process was 3.14 mm, p < 0.01. When the fluoroscopy angle was greater than 7.5°, the difference between fluoroscopy and CT measurements was greater than 3 mm for all landmarks.ConclusionsA fluoroscopy angle of 7.5° or more can lead to implant malposition greater than 3 mm. The pedicle is the most accurate of the anatomic landmarks studied for placement of total artificial discs in the lumbar spine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.