    Lung and diaphragm ultrasound as predictors of success in weaning from mechanical ventilation.

    • Eva Tenza-Lozano, Ana Llamas-Alvarez, Enrique Jaimez-Navarro, and Javier Fernández-Sánchez.
    • Intensive Care Unit, Department of Intensive Care Medicine, Elche General University Hospital, Camino de la Almazara 11, 03203, Elche, Spain. evitatl@hotmail.com.
    • Crit Ultrasound J. 2018 Jun 18; 10 (1): 12.

    BackgroundLung and diaphragm ultrasound methods have recently been introduced to predict the outcome of weaning from mechanical ventilation (MV). The aim of this study is to assess the reliability and accuracy of these techniques for predicting successful weaning in critically ill adults.MethodsWe conducted two studies: a cross-sectional interobserver agreement study between two sonographers and a prospective cohort study to assess the accuracy of lung and diaphragm ultrasound for predicting weaning and extubation outcome. For the interobserver agreement study, we included 50 general critical care patients who were consecutively admitted to the ICU. For the predictive accuracy study, we included consecutively 69 patients on MV who were ready for weaning. We assessed interobserver agreement of ultrasound measurements, using the weighted kappa coefficient for LUSm score (modified lung ultrasound score) and the intraclass correlation coefficient (ICC) and Bland-Altman method for TI (diaphragm thickening index). We assessed the predictive value of LUSm and TI in weaning outcome by plotting the corresponding ROC curves.ResultsWe found adequate interobserver agreement for both LUSm (weighted kappa 0.95) and TI (ICC 0.78, difference according to Bland-Altman analysis ± 12.5%). LUSm showed good-moderate discriminative power for successful weaning and extubation (area under the ROC curve (AUC) for successful weaning 0.80, and sensitivity and specificity at optimal cut-off point 0.76 and 0.73, respectively; AUC for successful extubation 0.78, and optimal sensitivity and specificity 0.76 and 0.47, respectively. TI was more sensitive but less specific for predicting successful weaning (AUC 0.71, optimal sensitivity and specificity 0.93 and 0.48) and successful extubation (AUC 0.76, optimal sensitivity and specificity 0.93 and 0.58). The area under the ROC curve for predicting weaning success was 0.83 for both ultrasound measurements together.ConclusionsInterobserver agreement was excellent for LUSm and moderate-good for TI. A low TI value or high LUSm value indicates high risk of weaning failure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.