J. Cardiovasc. Electrophysiol. · Dec 2019
Randomized Controlled Trial Observational StudyHigh-power application is associated with shorter procedure time and higher rate of first-pass pulmonary vein isolation in ablation index-guided atrial fibrillation ablation.
- Hideharu Okamatsu, Junjiro Koyama, Yoshirou Sakai, Koudai Negishi, Katsuhide Hayashi, Takuo Tsurugi, Yasuaki Tanaka, Koichi Nakao, Tomohiro Sakamoto, and Ken Okumura.
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan.
- J. Cardiovasc. Electrophysiol. 2019 Dec 1; 30 (12): 2751-2758.
BackgroundsAblation index (AI) is useful to complete circumferential pulmonary vein isolation (CPVI) for atrial fibrillation (AF), but the role of radiofrequency power in AI-guided CPVI remains to be elucidated.MethodsWe investigated 60 patients with AF undergoing AI-guided CPVI (mean age, 66 ± 9 years; nonparoxysmal AF in 16). The first 40 patients were randomly assigned to low-power (LP; n = 20) and medium-power (MP; n = 20) groups and the following 20 patients to high-power (HP). In LP, radiofrequency (RF) application was done at 30 W at the anterior and 20 W at the posterior left atrial (LA) wall, while in MP, it was at 40 W at the anterior and 30 W at the posterior LA wall. In HP, 50 W was applied at the anterior, 40 W at posterior LA wall and 30 W on the esophagus. At each ablation point, target AI was 400 at the anterior, 360 at the posterior LA wall, and 260 on the esophagus.ResultsThe time to complete both-side CPVI was shortest in HP (median, 40 minutes, interquartile range [IQR], 28-63) followed by MP (58 [49-83] minutes, P = .008 vs HP) and LP (84 [72-93] minutes, P = .002 vs MP). Higher RF power application significantly increased first-pass isolation rate (55% in LP, 80% in MP and 85% in HP, P = .002) and decreased LA-PV reconnection rate (10% in LP, 8% in MP, and 0% in HP, P = .03).ConclusionIn AI-guided PVI, the HP RF application can shorten the time to complete PVI with a high rate of first-pass isolation and a low rate of LA-PV reconnection.© 2019 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.