• Spine · Jun 2013

    Pretension effects of the Dynesys cord on the tissue responses and screw-spacer behaviors of the lumbosacral construct with hybrid fixation.

    • Chen-Ying Chien, Ching-Hong Tan, Tsai-Hsiung Lu, Shang-Chih Lin, Wen-Hsien Chuang, Ming-Chieh Chiang, Yuan-Ping Luh, and Yeung-Jen Chen.
    • Graduate Institute of Mechanical and Electrical Engineering, National Taipei University of Technology, Taipei, Taiwan.
    • Spine. 2013 Jun 1;38(13):E775-82.

    Study DesignThe pretension of the Dynesys cord was varied to evaluate its effects on both tissue responses and screw-spacer behaviors by the finite-element method.ObjectiveThis study aimed to provide detailed information about the motion-preserving and load-shielding mechanisms of the Dynesys screw-spacer joint.Summary Of Background DataIntuitively, higher cord pretension aims to ensure the occurrence of screw-spacer contact, thus making the spacer the transmitter of the vertebral loads. However, detailed investigations of the cord-pretension effects have not yet been carried out. METHODS.: Using a validated lumbosacral model, the moderately degenerative L4-L5 segment was instrumented by a static fixator and the Dynesys fixator was further used to bridge a mildly degenerative L3-L4 segment. The pre-tended cord was modeled as an elastic spring with 0- and 300-N pretensions. The disc range-of-motion, disc stress, facet force, bone-screw stress, and screw-spacer force were chosen as comparison indices. RESULTS.: At the transition and adjacent segments, the range-of-motion differences between the 2 pretensions were 7.7% and 2.0% on average, respectively. The mechanical differences at the transition and adjacent segments were 9.0% and 5.2% (disc stress) and 9.4% and 9.1% (facet force), respectively. The results indicated that the cord pretension has a minor effect on the adjacent segments in comparison with the transition segment. However, the stress at the screw hub and force of the screw-spacer contact of the 300-N pretension were increased by 33.7% and 316.5% on average than without pretension, respectively.ConclusionThe moment arm from the screw-cord center to the fulcrum is significantly less than that of vertebral loads. This leads to the minor effect of increasing the cord pretension on the responses of the adjacent segments. However, the cord pretension can significantly affect both screw-spacer force and bone-screw stress.Level Of Evidence4.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…