• Eur J Cardiothorac Surg · Mar 2004

    Randomized Controlled Trial Comparative Study Clinical Trial

    Relation between size of prosthesis and valve gradient: comparison of two aortic bioprosthesis.

    • Rainald Seitelberger, Jan Bialy, Roman Gottardi, Gernot Seebacher, Reinhard Moidl, Martina Mittelböck, Paul Simon, and Ernst Wolner.
    • Department of Cardio-Thoracic Surgery, Medical University Vienna, Allgemeines Krankenhaus, Waehringer Guertel 18-20, A-1090 Vienna, Austria. seitel@magnet.at
    • Eur J Cardiothorac Surg. 2004 Mar 1; 25 (3): 358-63.

    ObjectivesThe outcome of patients undergoing aortic valve replacement (AVR) may be affected by the influence of prosthesis-patient mismatch on left ventricular mass regression. However, due to the discrepancies in labeled valve size, size of sizer and actual valve dimension, it is difficult to compare different valve types. In order to perform an objective comparison, this study was designed to compare the hemodynamics of the Edwards Lifescience pericardial (ELP) and the Medtronic Mosaic porcine (MM) bioprosthesis between patients receiving the same valve size and between patients with the same aortic annulus diameter.MethodsThis prospective, randomized study was performed on 81 hospital survivors out of 86 patients undergoing AVR with either the ELP (n=39) or the MM (n=42) bioprosthesis. Intra-operative randomization was performed after the surgeon had excised the aortic valve, measured the size of the aortic annulus with three different sizers (ELP, MM and a set of metric sizers), and decided which size he would implant for either of the valve types. All valves were implanted in supra-annular position with the same implantation technique. Echocardiographic follow-up was performed early postoperatively and 6 months thereafter.ResultsIn 12 (31%) of the patients receiving the ELP-valve, as compared to 3 (7.1%) of the patients receiving the MM-valve, the labeled valve size was smaller than the aortic annulus diameter (P<0.05). Early postoperatively, mean (17.4+/-3.1 vs 20.3+/-3.6 mmHg) and peak gradients (30.1+/-4.8 vs 37.6+/-9.6 mmHg) for the 21 mm ELP-valve were lower than for the 21 mm MM-valve (P<0.05). All other hemodynamic parameters did not show significant differences at any time point. When the same aortic annulus diameter was taken as a reference, there were no significant hemodynamic differences between either valve type at any time point, regardless of the valve size implanted.ConclusionsThis study demonstrates that the hemodynamic performance of the ELP and the MM bioprosthesis are comparable when the same aortic annulus diameter is taken as a reference. The significant variabilities between different valve types with regard to labeled valve size, valve-sizer size and actual valve size have to be taken into account, when hemodynamic comparisons are performed.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…