• J. Infect. Chemother. · Jan 2021

    Effectiveness of personal protective equipment in preventing severe acute respiratory syndrome coronavirus 2 infection among healthcare workers.

    • Tetsuya Suzuki, Kayoko Hayakawa, Akira Ainai, Naoko Iwata-Yoshikawa, Kaori Sano, Noriyo Nagata, Tadaki Suzuki, Yuji Wakimoto, Yutaro Akiyama, Yusuke Miyazato, Keiji Nakamura, Satoshi Ide, Hidetoshi Nomoto, Takato Nakamoto, Masayuki Ota, Yuki Moriyama, Yuko Sugiki, Sho Saito, Shinichiro Morioka, Masahiro Ishikane, Noriko Kinoshita, Satoshi Kutsuna, and Norio Ohmagari.
    • Disease Control and Prevention Center, National Center for Global Health and Medicine, Tokyo, Japan; Emerging and Re-emerging Infectious Diseases, Graduate School of Medicine, Tohoku University, Sendai, Japan. Electronic address: tesuzuki@hosp.ncgm.go.jp.
    • J. Infect. Chemother. 2021 Jan 1; 27 (1): 120-122.

    IntroductionInformation on the effectiveness of personal protective equipment (PPE) for preventing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection among healthcare workers (HCWs), especially among HCWs with frequent contact with patients with SARS-CoV-2, is limited.MethodsWe conducted a prospective cohort study on 49 HCWs who worked in close contact with patients with SARS-CoV-2 infection. HCWs had blood samples taken every 2 weeks to test for SARS-CoV-2 antibodies using two different types of assay.ResultsForty-nine participants (31 nurses, 15 doctors, 3 other workers) were enrolled. In total, 112 blood samples are obtained from participants. The median work days in 2 weeks was 9 (interquartile range (IQR): 5-10) days. In a single work day, 30 of the 49 participants (61.5%) had contact with patients with suspected or conformed SARS-CoV-2 at least 8 times, and approximately 60% of participants had more than 10 min of contact with a single patient. The median self-reported compliance to PPE was 90% (IQR: 80-100%). Seven participants tested positive for SARS-CoV-2 antibody using enzyme-linked immunosorbent assay (ELISA); however, none were seropositive for SARS-CoV-2 neutralizing antibody, so the positive ELISA results were assumed to be false-positive.ConclusionsThe study provides evidence that appropriate PPE is sufficient to prevent infection amongHCWs. It is necessary to establish a system that provides a stable supply of PPE for HCWs to perform their duties.Copyright © 2020 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.