• Burns · Nov 2021

    Comparative Study

    Comparison between the portable pressure measuring device and PicoPress® for garment pressure measurement on hypertrophic burn scar during compression therapy.

    • Seung Yeol Lee, Yoon Soo Cho, So Young Joo, and Cheong Hoon Seo.
    • Department of Physical Medicine and Rehabilitation, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Republic of Korea.
    • Burns. 2021 Nov 1; 47 (7): 1621-1626.

    PurposeThe current standard treatment for hypertrophic scars following burn injury is pressure garment therapy. The experimenters developed the novel portable pressure measuring device using silicon piezoresistive sensors. As PicoPress® is the most accurate (i.e., lowest variation and error) manometric sensor for pressure measurement, we sought to compare and examine the accuracy of the novel device regarding in vitro pressure measurements at the hypertrophic scar-pressure garment interface.MethodsThe novel device was designed to operate in non-corrosive media, such as air. The device can use up to six pressure sensing points and was developed to adjust the number of pressure sensors according to the size of the scar. Pressure measurements were acquired through a readout circuit consisting of an analog-to-digital converter, a microprocessor, and a Bluetooth transmission module for wireless data transmission to an external device. All signals were converted into mean pressure expressed in millimeters of mercury (mmHg). The mean pressure values measured by the sensors were compared to those obtained from PicoPress®. 55 garment pressures recordings were obtained from the sensors over this study conducted in 2018-February 2020. We then analyzed the test-retest reliability using the intraclass correlation coefficients (ICC). PicoPress® was also employed in the same pressure garments for obtaining similar measurements. A two way random effects model ICC with 95% confidence intervals was used to compare the mean pressure values obtained from the silicon piezoresistive sensors to the PicoPress® measurements.ResultsThe test-retest reliability of the pressure sensors was close to the acceptable level for clinical use regarding stationary interface pressure measurement (ICC = 0.99, 95% CI 0.990-0.997). The mean pressure obtained from the silicon piezoresistive pressure sensors showed an accordance with the measurements from PicoPress® (ICC = 0.97, 95% CI 0.947-0.985).ConclusionThe novel device may present a viable alternative to PicoPress® for garment pressure measurements. In addition, the novel device improves adaptability to the hypertrophic scar shape and size. Complementary characteristics such as wireless transmission to an external device may allow burn patients to continuously wear the device for real-time measurements during pressure garment therapy, thus improving existing devices including PicoPress®.Copyright © 2021 Elsevier Ltd and ISBI. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.