    Impact of different syringe pumps on red cells during paediatric simulated transfusion.

    • Larissa Perez Pardo, PeterliniMaria Angélica SorginiMASDepartment of Paediatric Nursing, Paulista School of Nursing, Universidade Federal de São Paulo - UNIFESP, Sao Paulo, Brazil.Nursing Postgraduate Program, Paulista School of Nursing, UNIFESP, Sao Paulo, Brazil., Lyvonne Nicole Tume, and PedreiraMavilde Luz GonçalvesMLGDepartment of Paediatric Nursing, Paulista School of Nursing, Universidade Federal de São Paulo - UNIFESP, Sao Paulo, Brazil.Department of Paediatric Nursing, Paulista School of Nursing, Universidade Federal de São Paulo - .
    • Department of Nursing, Paulista University, Sao Paulo, Brazil.
    • Nurs Crit Care. 2020 Oct 23.

    BackgroundCritically ill patients frequently need blood transfusions. For safety, blood must be delivered via syringe infusion pumps, yet this can cause red cell damage and increase the rate of haemolysis.Aims And ObjectivesTo evaluate biochemical and haemolytic markers of red blood cells transfused in three different types of syringe infusion pumps at two different infusion rates (10 and 100 mL/h).Design And MethodsA lab-based study using aliquots of 16 red blood cell bags was undertaken. Haemolysis markers (total haemoglobin [g/dL], haematocrit [%], free haemoglobin [g/dL], potassium [mmol/L], lactate dehydrogenase [U/L], osmolality [mOsm/kg], pH, degree of haemolysis [%]) were measured before and after red blood cell infusion and exposure. Three different syringe infusion pumps brands (A, B, and C) were compared at two different infusion rates (10 and 100 mL/h).ResultsTotal haemoglobin fell significantly in all red blood cell units during manipulation (pre-infusion: 26.44 ± 5.74; post-exposure: 22.62 ± 4.00; P = .026). The degree of haemolysis significantly increased by 40% after manipulation of the red blood cells. Syringe infusion pump A caused a 3-fold increase in potassium levels (3.78 ± 6.10) when compared with B (-0.14 ± 1.46) and C (1.63 ± 1.98) (P = .015). This pump also produced the worst changes, with an increase in free haemoglobin (0.05 ± 0.05; P = .038) and more haemolysis (0.08 ± 0.07; P = .033). There were significant differences and an increase in the degree of haemolysis (P = .004) at the infusion rate of 100 mL/h.ConclusionsSyringe infusion pumps may cause significant red blood cell damage during infusion, with increases in free haemoglobin, potassium, and the degree of haemolysis. Some pump types, with a cassette mechanism, caused more damage.Relevance To Clinical PracticeIn many intensive care units, bedside nurses are able to consider infusion pump choice, and understanding the impact of different pump types on red blood cells during a transfusion provides the nurses with more information to enhance decision-making and improve the quality of the transfusion.© 2020 British Association of Critical Care Nurses.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…