• J Vet Emerg Crit Care (San Antonio) · Nov 2017

    Influence of catecholamines at different dosages on the function of the LiDCO sensor in isoflurane anesthetized horses.

    • Klaus Hopster, Tamas D Ambrisko, and Kästner Sabine B R SBR Equine Clinic, University of Veterinary Medicine Hanover, Hanover, Germany..
    • Equine Clinic, University of Veterinary Medicine Hanover, Hanover, Germany.
    • J Vet Emerg Crit Care (San Antonio). 2017 Nov 1; 27 (6): 651-657.

    ObjectiveTo compare the lithium dilution method for cardiac output (LiDCO) and bolus-thermo-dilution (BTD) measurements before and during infusion of dobutamine, dopamine, phenylephrine, or noradrenaline at 2 different doses in anesthetized horses and to examine the correlation between sensor voltages (saline-blood exposed) and possible measurement errors.DesignProspective experimental study.SettingUniversity teaching hospital.AnimalsNine Warmblood horses.InterventionsFollowing 90 minutes of equilibration, 3 different doses of dobutamine (0.5-3 μg/kg/min), dopamine (1-5 μg/kg/min), phenylephrine (0.5-3 μg/kg/min), or noradrenaline (0.1-0.5 μg/kg/min) were administered for 15 minutes in anesthetized horses, and measurements using the LiDCO were performed at the lowest and highest doses. Pairs of LiDCO and BTD measurements were collected and sensor voltages exposed to blood and saline were measured before and at the end of each infusion period. Agreement between LiDCO and BTD was assessed with the Bland-Altman method.Measurement And Main ResultsThe biases (2 standard deviations) before infusion of dobutamine, dopamine, phenylephrine, and noradrenaline were 1.1 (5.7), 1.6 (7.3), 0.2 (6.6), and 1.5 (4.1) L/min, respectively, and minimally and nonsignificantly changed following low-dose catecholamine infusions. Following infusion of higher doses, biases were significantly higher compared to baseline with 10.7 (7.8), 11.2 (11.9), 6.9 (11.7), and 3.5 (3.8) L/min, respectively. The difference between saline- and blood-exposed sensor voltage decreased during infusion of high doses of catecholamines with correlations (rs = 0.62) between cardiac output differences and sensor voltage differences (saline-blood).ConclusionsThis study demonstrated that catecholamines could lead to overestimation in a dose-dependent fashion in LiDCO measurements. Monitoring changes in sensor voltage differences (saline-blood) is a valuable and clinically applicable tool to predict errors in LiDCO measurements.© Veterinary Emergency and Critical Care Society 2017.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…