• Anasthesiol Intensivmed Notfallmed Schmerzther · Jun 2004

    Clinical Trial

    [The positioning of reinforced laryngeal masks (LMA) with the "Zerer-introducer"].

    • C Ehrensperger, J Gross, W Zerer, A Henn-Beilharz, and A Brodbeck.
    • Abteilung für Anästhesie und Intensivmedizin, Städt. Krankenhaus Sindelfingen. ehrensperger@onlinehome.de
    • Anasthesiol Intensivmed Notfallmed Schmerzther. 2004 Jun 1; 39 (6): 344-7.

    ObjectiveCorrect and rapid positioning of reinforced laryngeal masks (LMA) is often a problem in anaesthetics. Although different techniques have been developed, none of them are satisfactory. A newly designed introduction device was used to place reinforced laryngeal masks. These are first results of a clinical observational study.MethodsA special fork fixed on a handhold was constructed. The introduction of the LMA was possible in an arched movement down to the hypopharynx using appropriate sizes for different sizes of LMA's.ResultsThe intubation in 500 surgical cases (30 % adult, 70 % children, mostly in ENT-surgery) was easy and rapidly performed. A leading finger for placement was not necessary. There were neither cases of rotation nor retrograde flexion of the top of the mask. Direct vision by the ENT-specialist revealed no evidence of any injuries of the palate or throat.ConclusionA newly designed introduction device allows a fast and efficient placement of reinforced laryngeal masks and contributes to the safety of this mode of application.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.