-
Eur Heart J Cardiovasc Imaging · Jun 2019
Comparative StudyMITRA-FR vs. COAPT: lessons from two trials with diametrically opposed results.
- Philippe Pibarot, Victoria Delgado, and Jeroen J Bax.
- Institut Universitaire de Cardiologie et de Pneumologie de Québec/Québec Heart and Lung Institute, Department of Medicine, Université Laval, 2725 Chemin Sainte-Foy, Pavillon A Québec city, Québec, Canada.
- Eur Heart J Cardiovasc Imaging. 2019 Jun 1; 20 (6): 620-624.
AbstractPercutaneous mitral valve repair using the MitraClip device has been proposed to correct secondary mitral regurgitation (MR). Recently, the results of two randomized controlled trials, that is MITRA-FR (Percutaneous Repair with the MitraClip Device for Severe Functional/Secondary Mitral Regurgitation) and COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation), assessing the efficacy and safety of MitraClip in patients with systolic heart failure and severe secondary MR were published. A priori, these two trials targeted the same patient populations with the same disease using the same device but the results of these trials were diametrically opposed, MITRA-FR being neutral and COAPT being highly positive with respect to efficacy of the MitraClip procedure. The objectives of this viewpoint are: (i) to highlight not only the similarities but also the differences between MITRA-FR and COAPT, which may explain the strikingly different results and conclusions between these two trials and (ii) to derive from these results, implications with regards to the application of the MitraClip procedure in clinical practice.© The Author(s) 2019. Published by Oxford University Press on behalf of the European Society of Cardiology.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.