• Arch Orthop Trauma Surg · Dec 2013

    Case Reports

    Anterior screw fixation for an odontoid fracture using an Acutrak 4/5 screw: a case report.

    • Juichi Tonosu, Kenichi Watanabe, Hiroaki Abe, Akiro Higashikawa, Shinya Kato, and Koji Yamada.
    • Arch Orthop Trauma Surg. 2013 Dec 1;133(12):1681-6.

    AbstractThe direct anterior screw fixation of odontoid fractures by a single cancellous screw, especially for osteoporotic vertebrae, has a potential risk of leading to insufficient stability and implant failures. We experienced good results following surgery using a single Acutrak 4/5 screw to obtain sufficient stability for an odontoid fracture in a patient with osteopenia. The screw is a cannulated self-tapping headless screw and has a tapered profile and full threads with variable pitches, and it can yield sufficient compression force as the screw is inserted. The preoperative severe neck pain of the patient was diminished immediately after the surgery. The patient achieved bone union in a short time and had a good clinical result for at least 3 years. Some biomechanical studies showed that the compression force of Acutrak standard screws was stronger than that of both 4.0-mm cancellous screws inserted with the lag screw technique and Herbert screws, and other studies showed that the compression force of Acutrak 4/5 screws was equivalent to that of 4.5-mm cortical screws. However, there has been no clinical report of surgery using an Acutrak 4/5 screw for odontoid fractures. This is the first clinical report of fixation by an Acutrak 4/5 screw.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…